降压型PWM电导控制器的小信号、低频分析

A. Kislovski
{"title":"降压型PWM电导控制器的小信号、低频分析","authors":"A. Kislovski","doi":"10.1109/PESC.1990.131176","DOIUrl":null,"url":null,"abstract":"The small-signal, low-frequency control-voltage-to-output voltage transfer function of a buck cell utilizing the PWM (pulse width modulation) conductance control principle is derived, and its dependence on different circuit parameters is established. A numerical application shows close agreement with previously published data. The results obtained are used to compare the PWM conductance controller to its current-mode control counterpart utilizing a linear compensating ramp. Precise and comprehensive indications are given as to how the analysis applied can be used to investigate the dynamic loading imposed by the PWM conductance control cells on their input filters. The goal is to demonstrate the simplicity of the PWM conductance control principle's dynamic analysis when the method of characteristic coefficients is applied.<<ETX>>","PeriodicalId":330807,"journal":{"name":"21st Annual IEEE Conference on Power Electronics Specialists","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"Small-signal, low-frequency analysis of a buck type PWM conductance controller\",\"authors\":\"A. Kislovski\",\"doi\":\"10.1109/PESC.1990.131176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The small-signal, low-frequency control-voltage-to-output voltage transfer function of a buck cell utilizing the PWM (pulse width modulation) conductance control principle is derived, and its dependence on different circuit parameters is established. A numerical application shows close agreement with previously published data. The results obtained are used to compare the PWM conductance controller to its current-mode control counterpart utilizing a linear compensating ramp. Precise and comprehensive indications are given as to how the analysis applied can be used to investigate the dynamic loading imposed by the PWM conductance control cells on their input filters. The goal is to demonstrate the simplicity of the PWM conductance control principle's dynamic analysis when the method of characteristic coefficients is applied.<<ETX>>\",\"PeriodicalId\":330807,\"journal\":{\"name\":\"21st Annual IEEE Conference on Power Electronics Specialists\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"21st Annual IEEE Conference on Power Electronics Specialists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1990.131176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"21st Annual IEEE Conference on Power Electronics Specialists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1990.131176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

利用脉宽调制电导控制原理推导了buck电池的小信号、低频控制电压-输出电压传递函数,并建立了其对不同电路参数的依赖关系。数值计算结果与以前发表的数据非常吻合。所得结果用于比较PWM电导控制器与利用线性补偿斜坡的电流模式控制器。给出了精确和全面的指示,说明如何应用分析来研究PWM电导控制单元对其输入滤波器施加的动态负载。我们的目的是证明当应用特征系数方法时,PWM电导控制原理动态分析的简单性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Small-signal, low-frequency analysis of a buck type PWM conductance controller
The small-signal, low-frequency control-voltage-to-output voltage transfer function of a buck cell utilizing the PWM (pulse width modulation) conductance control principle is derived, and its dependence on different circuit parameters is established. A numerical application shows close agreement with previously published data. The results obtained are used to compare the PWM conductance controller to its current-mode control counterpart utilizing a linear compensating ramp. Precise and comprehensive indications are given as to how the analysis applied can be used to investigate the dynamic loading imposed by the PWM conductance control cells on their input filters. The goal is to demonstrate the simplicity of the PWM conductance control principle's dynamic analysis when the method of characteristic coefficients is applied.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信