{"title":"传统和多电平逆变器拓扑结构综述","authors":"Amir R. Adly, Hossam Y. Abdul-Hamid, Asmaa Elhussiny, M. Zaky, E. E. EL-Kholy","doi":"10.1109/CPERE56564.2023.10119633","DOIUrl":null,"url":null,"abstract":"The utilization of renewable energy resources using PV, wind turbines, and fuel cells, has grown significantly over the last decades in the power grids. This makes power electronic inverters an indispensable part of renewable energy systems as a necessary interface between these resources and the power grids. However, conventional two-level inverters (TLIs) cannot satisfy applications in high voltage ranges. Therefore, multilevel inverters (MLIs) are used for this purpose. MLIs have many advantages over conventional TLIs, particularly lower total harmonics distortion, lower electromagnetic interference, suitability for medium voltage-high power applications, minimizing dvldt across switches, higher efficiency, and larger DC link voltages. To align with high power demands, MLIs can create the desired number of levels. Recent MLIs topologies are produced with increased levels using fewer components resulting in cost minimization and increasing system reliability. Also, modulation techniques play a substantial role in improving the behavior of MLIs. This paper briefly reviews the different topologies of conventional TLIs and MLIs. A comparison between conventional TLI and MLIs is introduced. The basic concepts of the different topologies are discussed in detail. The merits, demerits, and applications of each topology are presented. The recent topologies of MLI are also highlighted. Control and modulation techniques are introduced.","PeriodicalId":169048,"journal":{"name":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Brief Review of the Conventional and Multilevel Inverters Topologies\",\"authors\":\"Amir R. Adly, Hossam Y. Abdul-Hamid, Asmaa Elhussiny, M. Zaky, E. E. EL-Kholy\",\"doi\":\"10.1109/CPERE56564.2023.10119633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The utilization of renewable energy resources using PV, wind turbines, and fuel cells, has grown significantly over the last decades in the power grids. This makes power electronic inverters an indispensable part of renewable energy systems as a necessary interface between these resources and the power grids. However, conventional two-level inverters (TLIs) cannot satisfy applications in high voltage ranges. Therefore, multilevel inverters (MLIs) are used for this purpose. MLIs have many advantages over conventional TLIs, particularly lower total harmonics distortion, lower electromagnetic interference, suitability for medium voltage-high power applications, minimizing dvldt across switches, higher efficiency, and larger DC link voltages. To align with high power demands, MLIs can create the desired number of levels. Recent MLIs topologies are produced with increased levels using fewer components resulting in cost minimization and increasing system reliability. Also, modulation techniques play a substantial role in improving the behavior of MLIs. This paper briefly reviews the different topologies of conventional TLIs and MLIs. A comparison between conventional TLI and MLIs is introduced. The basic concepts of the different topologies are discussed in detail. The merits, demerits, and applications of each topology are presented. The recent topologies of MLI are also highlighted. Control and modulation techniques are introduced.\",\"PeriodicalId\":169048,\"journal\":{\"name\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPERE56564.2023.10119633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPERE56564.2023.10119633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在过去的几十年里,可再生能源的利用,如光伏、风力涡轮机和燃料电池,在电网中有了显著的增长。这使得电力电子逆变器成为可再生能源系统中不可或缺的一部分,作为这些资源与电网之间的必要接口。然而,传统的双电平逆变器(TLIs)不能满足高电压范围的应用。因此,多电平逆变器(mli)用于此目的。与传统的tli相比,mli具有许多优点,特别是更低的总谐波失真,更低的电磁干扰,适合中压高功率应用,最大限度地减少开关间的dvldt,更高的效率和更大的直流链路电压。为了满足高功率需求,mli可以创建所需数量的电平。最近的mli拓扑结构使用更少的组件产生更高的级别,从而使成本最小化并提高了系统可靠性。此外,调制技术在改善mli的性能方面起着实质性的作用。本文简要回顾了传统tli和mli的不同拓扑结构。介绍了传统TLI和mli的比较。详细讨论了不同拓扑的基本概念。介绍了每种拓扑的优点、缺点和应用。本文还重点介绍了MLI的最新拓扑结构。介绍了控制和调制技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Brief Review of the Conventional and Multilevel Inverters Topologies
The utilization of renewable energy resources using PV, wind turbines, and fuel cells, has grown significantly over the last decades in the power grids. This makes power electronic inverters an indispensable part of renewable energy systems as a necessary interface between these resources and the power grids. However, conventional two-level inverters (TLIs) cannot satisfy applications in high voltage ranges. Therefore, multilevel inverters (MLIs) are used for this purpose. MLIs have many advantages over conventional TLIs, particularly lower total harmonics distortion, lower electromagnetic interference, suitability for medium voltage-high power applications, minimizing dvldt across switches, higher efficiency, and larger DC link voltages. To align with high power demands, MLIs can create the desired number of levels. Recent MLIs topologies are produced with increased levels using fewer components resulting in cost minimization and increasing system reliability. Also, modulation techniques play a substantial role in improving the behavior of MLIs. This paper briefly reviews the different topologies of conventional TLIs and MLIs. A comparison between conventional TLI and MLIs is introduced. The basic concepts of the different topologies are discussed in detail. The merits, demerits, and applications of each topology are presented. The recent topologies of MLI are also highlighted. Control and modulation techniques are introduced.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信