基于优化FACTS器件的电力系统电压角稳定性评估

A. Hemeida, A. Rashwan, H. Hasanien, T. Senjyu
{"title":"基于优化FACTS器件的电力系统电压角稳定性评估","authors":"A. Hemeida, A. Rashwan, H. Hasanien, T. Senjyu","doi":"10.1109/CPERE56564.2023.10119616","DOIUrl":null,"url":null,"abstract":"the paper presents the impacts of installing optimized PI controlled flexible AC transmission systems (FACTS) devices to improve voltage and angle stability of power systems. In the study static VAR compensator (SVC) is considered. The Henry Gas Solubility Optimization HGSO algorithm is applied to determine the optimum parameters of the proportional plus integral (PI) controller for SVC. Two different types of faults are considered to investigate the feasibility of installing optimized SVC devices in power systems to improve both angle and voltage stability. Three-phase short circuit fault is implemented at the generator terminals, and input mechanical disturbance are applied. The response indicate the superiority of the suggested HGSO controller over the conventional PI controller. Matlab software is used to solve the system equations.","PeriodicalId":169048,"journal":{"name":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Voltage and Angle Stability Assessment of Power Systems Based Optimizated FACTS Devices\",\"authors\":\"A. Hemeida, A. Rashwan, H. Hasanien, T. Senjyu\",\"doi\":\"10.1109/CPERE56564.2023.10119616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"the paper presents the impacts of installing optimized PI controlled flexible AC transmission systems (FACTS) devices to improve voltage and angle stability of power systems. In the study static VAR compensator (SVC) is considered. The Henry Gas Solubility Optimization HGSO algorithm is applied to determine the optimum parameters of the proportional plus integral (PI) controller for SVC. Two different types of faults are considered to investigate the feasibility of installing optimized SVC devices in power systems to improve both angle and voltage stability. Three-phase short circuit fault is implemented at the generator terminals, and input mechanical disturbance are applied. The response indicate the superiority of the suggested HGSO controller over the conventional PI controller. Matlab software is used to solve the system equations.\",\"PeriodicalId\":169048,\"journal\":{\"name\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPERE56564.2023.10119616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPERE56564.2023.10119616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了安装优化的PI控制柔性交流输电系统(FACTS)装置对提高电力系统电压和角度稳定性的影响。研究中考虑了静态无功补偿器(SVC)。采用Henry气体溶解度优化HGSO算法确定SVC比例积分(PI)控制器的最优参数。考虑了两种不同类型的故障,探讨了在电力系统中安装优化的SVC装置以提高角度和电压稳定性的可行性。在发电机端子处发生三相短路故障,并施加输入机械扰动。响应结果表明,所提出的HGSO控制器优于传统的PI控制器。利用Matlab软件对系统方程进行求解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage and Angle Stability Assessment of Power Systems Based Optimizated FACTS Devices
the paper presents the impacts of installing optimized PI controlled flexible AC transmission systems (FACTS) devices to improve voltage and angle stability of power systems. In the study static VAR compensator (SVC) is considered. The Henry Gas Solubility Optimization HGSO algorithm is applied to determine the optimum parameters of the proportional plus integral (PI) controller for SVC. Two different types of faults are considered to investigate the feasibility of installing optimized SVC devices in power systems to improve both angle and voltage stability. Three-phase short circuit fault is implemented at the generator terminals, and input mechanical disturbance are applied. The response indicate the superiority of the suggested HGSO controller over the conventional PI controller. Matlab software is used to solve the system equations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信