基于可再生能源的并联有源电力滤波器电能质量分析

Anand Singh, P. Baredar
{"title":"基于可再生能源的并联有源电力滤波器电能质量分析","authors":"Anand Singh, P. Baredar","doi":"10.1109/ICAETR.2014.7012836","DOIUrl":null,"url":null,"abstract":"Electrical power provides feeds different kind of linear and non-linear loads in commercial and manufacturing applications. The electronics loads produce harmonics and reactive power related problems in the electrical utility systems. The power quality disturbance just like harmonic and reactive power cause poor power factor and distort the source voltage at the consumer service end. In this work, we propose a solution to eliminate the current harmonics introduced by the nonlinear loads, used shunt active power filter supplied by a renewable energy source. The shunt active power filter shows a strong vitality in eliminating harmonics and reactive power, which has received extensive concern in power electronic filed. Most of the using shunt active power filters are based on voltage source inverter. The DC-link voltage of inverter must be kept stable in order that SAPF can compensate harmonics and reactive power effectively. In this paper we developed MATLAB® Simulink model of a typical power distribution system with a nonlinear load and shunt active power filter is carried out and the results are presented which imply a better dynamic performance of the proposed scheme to the conventional PI controller.","PeriodicalId":196504,"journal":{"name":"2014 International Conference on Advances in Engineering & Technology Research (ICAETR - 2014)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Power quality analysis of shunt active power filter based on renewable energy source\",\"authors\":\"Anand Singh, P. Baredar\",\"doi\":\"10.1109/ICAETR.2014.7012836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical power provides feeds different kind of linear and non-linear loads in commercial and manufacturing applications. The electronics loads produce harmonics and reactive power related problems in the electrical utility systems. The power quality disturbance just like harmonic and reactive power cause poor power factor and distort the source voltage at the consumer service end. In this work, we propose a solution to eliminate the current harmonics introduced by the nonlinear loads, used shunt active power filter supplied by a renewable energy source. The shunt active power filter shows a strong vitality in eliminating harmonics and reactive power, which has received extensive concern in power electronic filed. Most of the using shunt active power filters are based on voltage source inverter. The DC-link voltage of inverter must be kept stable in order that SAPF can compensate harmonics and reactive power effectively. In this paper we developed MATLAB® Simulink model of a typical power distribution system with a nonlinear load and shunt active power filter is carried out and the results are presented which imply a better dynamic performance of the proposed scheme to the conventional PI controller.\",\"PeriodicalId\":196504,\"journal\":{\"name\":\"2014 International Conference on Advances in Engineering & Technology Research (ICAETR - 2014)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Advances in Engineering & Technology Research (ICAETR - 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAETR.2014.7012836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Advances in Engineering & Technology Research (ICAETR - 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAETR.2014.7012836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

电力在商业和制造应用中提供不同种类的线性和非线性负载。在电力系统中,电子负载产生谐波和无功功率的相关问题。电能质量扰动与谐波、无功一样,会造成用户服务端的功率因数差和源电压畸变。在这项工作中,我们提出了一种解决方案,消除由非线性负载引入的电流谐波,使用可再生能源供电的并联有源电力滤波器。并联型有源电力滤波器在消除谐波和无功功率方面显示出强大的生命力,受到电力电子领域的广泛关注。大多数采用并联型有源滤波器的逆变器都是基于电压源的。为了有效地补偿谐波和无功功率,必须保持逆变器直流电压的稳定。本文利用MATLAB®Simulink建立了一个典型的具有非线性负载的配电系统的模型,并对并联有源电力滤波器进行了仿真,结果表明该方案比传统的PI控制器具有更好的动态性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power quality analysis of shunt active power filter based on renewable energy source
Electrical power provides feeds different kind of linear and non-linear loads in commercial and manufacturing applications. The electronics loads produce harmonics and reactive power related problems in the electrical utility systems. The power quality disturbance just like harmonic and reactive power cause poor power factor and distort the source voltage at the consumer service end. In this work, we propose a solution to eliminate the current harmonics introduced by the nonlinear loads, used shunt active power filter supplied by a renewable energy source. The shunt active power filter shows a strong vitality in eliminating harmonics and reactive power, which has received extensive concern in power electronic filed. Most of the using shunt active power filters are based on voltage source inverter. The DC-link voltage of inverter must be kept stable in order that SAPF can compensate harmonics and reactive power effectively. In this paper we developed MATLAB® Simulink model of a typical power distribution system with a nonlinear load and shunt active power filter is carried out and the results are presented which imply a better dynamic performance of the proposed scheme to the conventional PI controller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信