局部血流分布控制的微型机器人连续牛卵母细胞去核

Lin Feng, A. Ichikawa, F. Arai, M. Hagiwara
{"title":"局部血流分布控制的微型机器人连续牛卵母细胞去核","authors":"Lin Feng, A. Ichikawa, F. Arai, M. Hagiwara","doi":"10.1109/3M-NANO.2012.6472969","DOIUrl":null,"url":null,"abstract":"We present a continuous enucleation process of bovine oocytes on a microfluidic chip to achieve the continuous cutting of the oocytes and increasing the potential viability of the enucleated oocyte. By combining microfluidic chip and micororobotics, the flow in a channel can be actively controlled and we achieved successive operations of 1) loading oocyte, 2) control cutting volume and 3) removing nucleus. The magnetically actuated microrobot can control local fluid flow by changing its position like gate valve and control fluid force distributions in a microchip which govern oocyte movement in a chip. The optimally designed microchannel for enucleation enables continuous operation and cutting bovine oocyte with smooth manner by hydrodynamic force. The new system is propose here to show advantages by the means of the continuous operation on oocytes in a short term, cutting precision and great potentiality on continuous enucleation process for clone technology.","PeriodicalId":134364,"journal":{"name":"2012 International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Continuous enucleation of bovine oocyte by microrobot with local flow distribution control\",\"authors\":\"Lin Feng, A. Ichikawa, F. Arai, M. Hagiwara\",\"doi\":\"10.1109/3M-NANO.2012.6472969\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a continuous enucleation process of bovine oocytes on a microfluidic chip to achieve the continuous cutting of the oocytes and increasing the potential viability of the enucleated oocyte. By combining microfluidic chip and micororobotics, the flow in a channel can be actively controlled and we achieved successive operations of 1) loading oocyte, 2) control cutting volume and 3) removing nucleus. The magnetically actuated microrobot can control local fluid flow by changing its position like gate valve and control fluid force distributions in a microchip which govern oocyte movement in a chip. The optimally designed microchannel for enucleation enables continuous operation and cutting bovine oocyte with smooth manner by hydrodynamic force. The new system is propose here to show advantages by the means of the continuous operation on oocytes in a short term, cutting precision and great potentiality on continuous enucleation process for clone technology.\",\"PeriodicalId\":134364,\"journal\":{\"name\":\"2012 International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/3M-NANO.2012.6472969\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/3M-NANO.2012.6472969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

我们提出了一种牛卵母细胞在微流控芯片上的连续去核过程,以实现卵母细胞的连续切割和增加去核卵母细胞的潜在生存能力。将微流控芯片与微型机器人相结合,实现了通道内流动的主动控制,实现了1)加载卵母细胞、2)控制切割体积、3)去除细胞核的连续操作。磁驱动微型机器人可以像闸阀一样通过改变其位置来控制局部流体流动,并控制芯片内的流体力分布,从而控制芯片内卵母细胞的运动。优化设计的去核微通道,利用水动力使牛卵母细胞能够连续操作,切割平滑。该系统具有短时间内对卵母细胞进行连续操作,切割精度高,在克隆技术的连续去核过程中具有很大的潜力等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Continuous enucleation of bovine oocyte by microrobot with local flow distribution control
We present a continuous enucleation process of bovine oocytes on a microfluidic chip to achieve the continuous cutting of the oocytes and increasing the potential viability of the enucleated oocyte. By combining microfluidic chip and micororobotics, the flow in a channel can be actively controlled and we achieved successive operations of 1) loading oocyte, 2) control cutting volume and 3) removing nucleus. The magnetically actuated microrobot can control local fluid flow by changing its position like gate valve and control fluid force distributions in a microchip which govern oocyte movement in a chip. The optimally designed microchannel for enucleation enables continuous operation and cutting bovine oocyte with smooth manner by hydrodynamic force. The new system is propose here to show advantages by the means of the continuous operation on oocytes in a short term, cutting precision and great potentiality on continuous enucleation process for clone technology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信