湿度和抗静电添加剂对变压器板影响的介电测量

Y. Du, M. Zahn, B. Lesieutre
{"title":"湿度和抗静电添加剂对变压器板影响的介电测量","authors":"Y. Du, M. Zahn, B. Lesieutre","doi":"10.1109/CEIDP.1997.634600","DOIUrl":null,"url":null,"abstract":"Moisture in solid insulation has detrimental effects on transformer life. When the system is not in equilibrium laboratory measurements with multiple wavelength interdigital sensors using the imposed frequency-wavenumber (/spl omega/-k) dielectrometry technique have proved to be an effective way to measure complex permittivity distribution in solid insulation which is directly related to the moisture distribution. Measurements of oil-free and oil-impregnated pressboard using interdigital sensors with changes in ambient moisture concentration are presented. A comparison between existing moisture equilibrium curves for the oil-paper system and experimental results is given. Measurements are also performed for anti-static additive in oil and the dielectrometry effects are discussed.","PeriodicalId":176239,"journal":{"name":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Dielectrometry measurements of effects of moisture and anti-static additive on transformer board\",\"authors\":\"Y. Du, M. Zahn, B. Lesieutre\",\"doi\":\"10.1109/CEIDP.1997.634600\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Moisture in solid insulation has detrimental effects on transformer life. When the system is not in equilibrium laboratory measurements with multiple wavelength interdigital sensors using the imposed frequency-wavenumber (/spl omega/-k) dielectrometry technique have proved to be an effective way to measure complex permittivity distribution in solid insulation which is directly related to the moisture distribution. Measurements of oil-free and oil-impregnated pressboard using interdigital sensors with changes in ambient moisture concentration are presented. A comparison between existing moisture equilibrium curves for the oil-paper system and experimental results is given. Measurements are also performed for anti-static additive in oil and the dielectrometry effects are discussed.\",\"PeriodicalId\":176239,\"journal\":{\"name\":\"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1997.634600\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1997.634600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

固体绝缘中的水分对变压器的寿命有不利影响。当系统处于非平衡状态时,采用多波长间数字传感器进行的附加频率-波数(/spl ω /-k)介电测量技术是测量固体绝缘中与水分分布直接相关的复介电常数分布的有效方法。介绍了利用数字间传感器随环境湿度变化对无油和浸渍纸板进行测量的方法。将现有的油纸系统水分平衡曲线与实验结果进行了比较。对油中抗静电添加剂进行了测试,并讨论了介电效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dielectrometry measurements of effects of moisture and anti-static additive on transformer board
Moisture in solid insulation has detrimental effects on transformer life. When the system is not in equilibrium laboratory measurements with multiple wavelength interdigital sensors using the imposed frequency-wavenumber (/spl omega/-k) dielectrometry technique have proved to be an effective way to measure complex permittivity distribution in solid insulation which is directly related to the moisture distribution. Measurements of oil-free and oil-impregnated pressboard using interdigital sensors with changes in ambient moisture concentration are presented. A comparison between existing moisture equilibrium curves for the oil-paper system and experimental results is given. Measurements are also performed for anti-static additive in oil and the dielectrometry effects are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信