{"title":"乳腺断层摄影CMOS有源像素传感器的噪声分析","authors":"M. Izadi, K. Karim","doi":"10.1109/IWSOC.2005.86","DOIUrl":null,"url":null,"abstract":"Crystalline silicon (c-Si) technology is attractive for advanced large area imaging applications because of higher transistor mobility, smaller feature sizes and higher density of integration. In particular, for advanced mammography modalities such as tomosynthesis, c-Si is ideally suited to develop the high performance circuitry required for higher contrast, lower noise, and lower X-ray dose, while providing high resolution pixels. We present a voltage-mediated active pixel sensor (APS) with a focus on large area, diagnostic medical X-ray tomographic mammography. System level noise calculations indicate that CMOS technology can meet the stringent noise and area requirements required for tomographic mammography.","PeriodicalId":328550,"journal":{"name":"Fifth International Workshop on System-on-Chip for Real-Time Applications (IWSOC'05)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Noise analysis of a CMOS active pixel sensor for tomographic mammography\",\"authors\":\"M. Izadi, K. Karim\",\"doi\":\"10.1109/IWSOC.2005.86\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Crystalline silicon (c-Si) technology is attractive for advanced large area imaging applications because of higher transistor mobility, smaller feature sizes and higher density of integration. In particular, for advanced mammography modalities such as tomosynthesis, c-Si is ideally suited to develop the high performance circuitry required for higher contrast, lower noise, and lower X-ray dose, while providing high resolution pixels. We present a voltage-mediated active pixel sensor (APS) with a focus on large area, diagnostic medical X-ray tomographic mammography. System level noise calculations indicate that CMOS technology can meet the stringent noise and area requirements required for tomographic mammography.\",\"PeriodicalId\":328550,\"journal\":{\"name\":\"Fifth International Workshop on System-on-Chip for Real-Time Applications (IWSOC'05)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-07-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fifth International Workshop on System-on-Chip for Real-Time Applications (IWSOC'05)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IWSOC.2005.86\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fifth International Workshop on System-on-Chip for Real-Time Applications (IWSOC'05)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IWSOC.2005.86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Noise analysis of a CMOS active pixel sensor for tomographic mammography
Crystalline silicon (c-Si) technology is attractive for advanced large area imaging applications because of higher transistor mobility, smaller feature sizes and higher density of integration. In particular, for advanced mammography modalities such as tomosynthesis, c-Si is ideally suited to develop the high performance circuitry required for higher contrast, lower noise, and lower X-ray dose, while providing high resolution pixels. We present a voltage-mediated active pixel sensor (APS) with a focus on large area, diagnostic medical X-ray tomographic mammography. System level noise calculations indicate that CMOS technology can meet the stringent noise and area requirements required for tomographic mammography.