用小波变换检测变压器上电过程中匝间故障

J. C. Olivares-Galvan, R. Escarela-Perez, J. A. González, J. C. Jacobo, D. Guillen, F. Espino-cortes
{"title":"用小波变换检测变压器上电过程中匝间故障","authors":"J. C. Olivares-Galvan, R. Escarela-Perez, J. A. González, J. C. Jacobo, D. Guillen, F. Espino-cortes","doi":"10.1109/ROPEC.2016.7830612","DOIUrl":null,"url":null,"abstract":"Interturn faults are a critical problem in power transformers that can eventually escalate into catastrophic faults and probably result in an overall network failure. Also, failures in transformer windings are still a major cause of transformer outages, and failure rates vary widely between different countries and systems, depending on many factors. Therefore, in this work, interturn faults with various levels of severity were imposed on the winding of a 120 VA, 24/125 V dry type transformer to diagnose it. The obtained signals during the experiments are processed using the Wavelet Transform and correlation modes. This technique only takes into account the high frequency information produced during the energization of a winding with interturn faults.","PeriodicalId":166098,"journal":{"name":"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Detection of interturn faults during transformer energization using wavelet transform\",\"authors\":\"J. C. Olivares-Galvan, R. Escarela-Perez, J. A. González, J. C. Jacobo, D. Guillen, F. Espino-cortes\",\"doi\":\"10.1109/ROPEC.2016.7830612\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Interturn faults are a critical problem in power transformers that can eventually escalate into catastrophic faults and probably result in an overall network failure. Also, failures in transformer windings are still a major cause of transformer outages, and failure rates vary widely between different countries and systems, depending on many factors. Therefore, in this work, interturn faults with various levels of severity were imposed on the winding of a 120 VA, 24/125 V dry type transformer to diagnose it. The obtained signals during the experiments are processed using the Wavelet Transform and correlation modes. This technique only takes into account the high frequency information produced during the energization of a winding with interturn faults.\",\"PeriodicalId\":166098,\"journal\":{\"name\":\"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROPEC.2016.7830612\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROPEC.2016.7830612","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

匝间故障是电力变压器中的一个关键问题,它最终会升级为灾难性故障,并可能导致整个电网的故障。此外,变压器绕组故障仍然是变压器停机的主要原因,不同国家和系统的故障率差异很大,这取决于许多因素。因此,本研究对一台120va, 24/ 125v干式变压器的绕组进行了不同程度的匝间故障诊断。对实验中得到的信号进行小波变换和相关模态处理。该方法只考虑了绕组匝间故障通电时产生的高频信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of interturn faults during transformer energization using wavelet transform
Interturn faults are a critical problem in power transformers that can eventually escalate into catastrophic faults and probably result in an overall network failure. Also, failures in transformer windings are still a major cause of transformer outages, and failure rates vary widely between different countries and systems, depending on many factors. Therefore, in this work, interturn faults with various levels of severity were imposed on the winding of a 120 VA, 24/125 V dry type transformer to diagnose it. The obtained signals during the experiments are processed using the Wavelet Transform and correlation modes. This technique only takes into account the high frequency information produced during the energization of a winding with interturn faults.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信