Eusébio Conceiçã, João Gomes, M. Lúcio, M. Conceição, H. Awbi
{"title":"城市外部环境条件对建筑窗户性能影响的数值模拟","authors":"Eusébio Conceiçã, João Gomes, M. Lúcio, M. Conceição, H. Awbi","doi":"10.32438/wpe.0320","DOIUrl":null,"url":null,"abstract":"This paper presents a numerical study of the influence of external urban environmental conditions, namely, the solar radiation, in the building windows performance. A software that simulates the building thermal behaviour with complex topology, in transient conditions, is developed and used in the study of indoor air quality and indoor thermal comfort of the occupants of a building, under typical summer conditions. As management strategy was implemented a control system to the Heating, Ventilation and Air Conditioning (HVAC) using the PMV (Predicted Mean Vote) index as controllable variable. The studied university building is located in a Mediterranean-type climate in the south of Portugal. The indoor thermal comfort, evaluated by the PMV index, and the indoor air quality, evaluated by the carbon dioxide concentration, were obtained for all occupied spaces. In order to evaluate the implemented control strategy a set of results was obtained for the situations with and without HVAC system control. To exemplify the results obtained, two large compartments were chosen, one with windows facing South and the other without windows. As main conclusion, it can be stated that the use of the HVAC system controllable by the PMV index allows acceptable levels of thermal comfort within the category C of the ISO 7730 standard, and acceptable levels of indoor air quality within the limit proposed by the ASHRAE 62.1 standard.","PeriodicalId":177785,"journal":{"name":"WEENTECH Proceedings in Energy","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical simulation of the influence of external urban environmental conditions in the building windows performance\",\"authors\":\"Eusébio Conceiçã, João Gomes, M. Lúcio, M. Conceição, H. Awbi\",\"doi\":\"10.32438/wpe.0320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a numerical study of the influence of external urban environmental conditions, namely, the solar radiation, in the building windows performance. A software that simulates the building thermal behaviour with complex topology, in transient conditions, is developed and used in the study of indoor air quality and indoor thermal comfort of the occupants of a building, under typical summer conditions. As management strategy was implemented a control system to the Heating, Ventilation and Air Conditioning (HVAC) using the PMV (Predicted Mean Vote) index as controllable variable. The studied university building is located in a Mediterranean-type climate in the south of Portugal. The indoor thermal comfort, evaluated by the PMV index, and the indoor air quality, evaluated by the carbon dioxide concentration, were obtained for all occupied spaces. In order to evaluate the implemented control strategy a set of results was obtained for the situations with and without HVAC system control. To exemplify the results obtained, two large compartments were chosen, one with windows facing South and the other without windows. As main conclusion, it can be stated that the use of the HVAC system controllable by the PMV index allows acceptable levels of thermal comfort within the category C of the ISO 7730 standard, and acceptable levels of indoor air quality within the limit proposed by the ASHRAE 62.1 standard.\",\"PeriodicalId\":177785,\"journal\":{\"name\":\"WEENTECH Proceedings in Energy\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"WEENTECH Proceedings in Energy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32438/wpe.0320\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"WEENTECH Proceedings in Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32438/wpe.0320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文对城市外部环境条件(即太阳辐射)对建筑窗户性能的影响进行了数值研究。开发了一种软件,用于模拟具有复杂拓扑结构的建筑物在瞬态条件下的热行为,并用于研究典型夏季条件下建筑物居住者的室内空气质量和室内热舒适性。随着管理策略的实施,建立了以PMV (Predicted Mean Vote)指数为可控变量的暖通空调(HVAC)控制系统。该研究的大学建筑位于葡萄牙南部的地中海型气候。以PMV指数评价室内热舒适性,以二氧化碳浓度评价室内空气质量。为了对实施的控制策略进行评价,得到了一组有和无暖通空调系统控制情况下的结果。为了举例说明所获得的结果,选择了两个大隔间,一个窗户朝南,另一个没有窗户。作为主要结论,可以这样说,使用由PMV指数控制的暖通空调系统,可接受的热舒适水平在ISO 7730标准的C类范围内,可接受的室内空气质量水平在ASHRAE 62.1标准提出的限制范围内。
Numerical simulation of the influence of external urban environmental conditions in the building windows performance
This paper presents a numerical study of the influence of external urban environmental conditions, namely, the solar radiation, in the building windows performance. A software that simulates the building thermal behaviour with complex topology, in transient conditions, is developed and used in the study of indoor air quality and indoor thermal comfort of the occupants of a building, under typical summer conditions. As management strategy was implemented a control system to the Heating, Ventilation and Air Conditioning (HVAC) using the PMV (Predicted Mean Vote) index as controllable variable. The studied university building is located in a Mediterranean-type climate in the south of Portugal. The indoor thermal comfort, evaluated by the PMV index, and the indoor air quality, evaluated by the carbon dioxide concentration, were obtained for all occupied spaces. In order to evaluate the implemented control strategy a set of results was obtained for the situations with and without HVAC system control. To exemplify the results obtained, two large compartments were chosen, one with windows facing South and the other without windows. As main conclusion, it can be stated that the use of the HVAC system controllable by the PMV index allows acceptable levels of thermal comfort within the category C of the ISO 7730 standard, and acceptable levels of indoor air quality within the limit proposed by the ASHRAE 62.1 standard.