{"title":"人工膝关节磨损与失效抑制研究进展","authors":"Wenhui Chen, Yu-cheng Guo, Yimo Han, Xupeng Wang","doi":"10.1145/3570773.3570879","DOIUrl":null,"url":null,"abstract":"In this paper, the problem of wear and failure for artificial knee joint are reviewed; Firstly, total knee arthroplasty (TKA) is described in detail. Secondly, the geometric design of the prosthesis, material properties and surface treatment are fully elaborated. Then, the laws of joint friction and wear, contact stress distribution, as well as lower limb force line change are summarized. Finally, three methods are concluded and advised to restrain the wear and failure for artificial knee, and the real-time monitoring equipment is recommended can be implanted in the patient's body to record the actual use of the prosthesis. The results of this study can provide theoretical support for the matching design, inhibition of friction and wear to artificial knee joint.","PeriodicalId":153475,"journal":{"name":"Proceedings of the 3rd International Symposium on Artificial Intelligence for Medicine Sciences","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A review on the wear and failure suppression of artificial knee joint\",\"authors\":\"Wenhui Chen, Yu-cheng Guo, Yimo Han, Xupeng Wang\",\"doi\":\"10.1145/3570773.3570879\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the problem of wear and failure for artificial knee joint are reviewed; Firstly, total knee arthroplasty (TKA) is described in detail. Secondly, the geometric design of the prosthesis, material properties and surface treatment are fully elaborated. Then, the laws of joint friction and wear, contact stress distribution, as well as lower limb force line change are summarized. Finally, three methods are concluded and advised to restrain the wear and failure for artificial knee, and the real-time monitoring equipment is recommended can be implanted in the patient's body to record the actual use of the prosthesis. The results of this study can provide theoretical support for the matching design, inhibition of friction and wear to artificial knee joint.\",\"PeriodicalId\":153475,\"journal\":{\"name\":\"Proceedings of the 3rd International Symposium on Artificial Intelligence for Medicine Sciences\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 3rd International Symposium on Artificial Intelligence for Medicine Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3570773.3570879\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 3rd International Symposium on Artificial Intelligence for Medicine Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3570773.3570879","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文综述了人工膝关节的磨损与失效问题;首先,详细介绍了全膝关节置换术(TKA)。其次,对假体的几何设计、材料性能和表面处理进行了全面阐述。总结了关节摩擦磨损规律、接触应力分布规律以及下肢受力线变化规律。最后总结出三种抑制人工膝关节磨损失效的方法,并建议可在患者体内植入实时监测设备,记录假体的实际使用情况。研究结果可为人工膝关节的匹配设计、抑制摩擦磨损提供理论支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A review on the wear and failure suppression of artificial knee joint
In this paper, the problem of wear and failure for artificial knee joint are reviewed; Firstly, total knee arthroplasty (TKA) is described in detail. Secondly, the geometric design of the prosthesis, material properties and surface treatment are fully elaborated. Then, the laws of joint friction and wear, contact stress distribution, as well as lower limb force line change are summarized. Finally, three methods are concluded and advised to restrain the wear and failure for artificial knee, and the real-time monitoring equipment is recommended can be implanted in the patient's body to record the actual use of the prosthesis. The results of this study can provide theoretical support for the matching design, inhibition of friction and wear to artificial knee joint.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信