{"title":"高压直流换流变压器绝缘热老化评价","authors":"D. Grant, W. McDermid","doi":"10.1109/ELINSL.2004.1380535","DOIUrl":null,"url":null,"abstract":"An HVDC converter transformer was removed from service and salvaged after 24 years of service. It had not experienced an in-service failure, although others from the same family had failed as a result of overheating. The salvage of the transformer provided an opportunity to observe signs of overheated cellulose, to take paper samples for DP measurements, and to assess the mechanical strength of the bonded CTC.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Assessment of thermal aging of HVDC converter transformer insulation\",\"authors\":\"D. Grant, W. McDermid\",\"doi\":\"10.1109/ELINSL.2004.1380535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An HVDC converter transformer was removed from service and salvaged after 24 years of service. It had not experienced an in-service failure, although others from the same family had failed as a result of overheating. The salvage of the transformer provided an opportunity to observe signs of overheated cellulose, to take paper samples for DP measurements, and to assess the mechanical strength of the bonded CTC.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment of thermal aging of HVDC converter transformer insulation
An HVDC converter transformer was removed from service and salvaged after 24 years of service. It had not experienced an in-service failure, although others from the same family had failed as a result of overheating. The salvage of the transformer provided an opportunity to observe signs of overheated cellulose, to take paper samples for DP measurements, and to assess the mechanical strength of the bonded CTC.