{"title":"光伏入网CIGRE居民低压电网谐波畸变评价","authors":"J. Castellanos, D. Patiño, C. Correa-Flórez, G. Ordóñez-Plata","doi":"10.1109/IAS44978.2020.9334760","DOIUrl":null,"url":null,"abstract":"This document presents an evaluation of harmonic distortion of the European CIGRE residential low voltage bench-mark network when considering distributed generation analysis. With the purpose of analyzing the photovoltaic penetration effects in a low voltage distribution network related with harmonic distortion, the network was modified changing the energy distributed resources by photovoltaic systems. Five scenarios of photovoltaic penetration are proposed, in all of them, the position of the photovoltaic systems is conserved, and the power of the systems varies in 1%, 5%, 15%, 30% and 50% with respect to the MV/LV transformer rating. The network was simulated with OpenDSS in combination with Python, in order to dynamically evaluate the harmonic distortion.","PeriodicalId":115239,"journal":{"name":"2020 IEEE Industry Applications Society Annual Meeting","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of Harmonic Distortion in the CIGRE Residential Low Voltage Network with Photovoltaic Penetration\",\"authors\":\"J. Castellanos, D. Patiño, C. Correa-Flórez, G. Ordóñez-Plata\",\"doi\":\"10.1109/IAS44978.2020.9334760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This document presents an evaluation of harmonic distortion of the European CIGRE residential low voltage bench-mark network when considering distributed generation analysis. With the purpose of analyzing the photovoltaic penetration effects in a low voltage distribution network related with harmonic distortion, the network was modified changing the energy distributed resources by photovoltaic systems. Five scenarios of photovoltaic penetration are proposed, in all of them, the position of the photovoltaic systems is conserved, and the power of the systems varies in 1%, 5%, 15%, 30% and 50% with respect to the MV/LV transformer rating. The network was simulated with OpenDSS in combination with Python, in order to dynamically evaluate the harmonic distortion.\",\"PeriodicalId\":115239,\"journal\":{\"name\":\"2020 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS44978.2020.9334760\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS44978.2020.9334760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of Harmonic Distortion in the CIGRE Residential Low Voltage Network with Photovoltaic Penetration
This document presents an evaluation of harmonic distortion of the European CIGRE residential low voltage bench-mark network when considering distributed generation analysis. With the purpose of analyzing the photovoltaic penetration effects in a low voltage distribution network related with harmonic distortion, the network was modified changing the energy distributed resources by photovoltaic systems. Five scenarios of photovoltaic penetration are proposed, in all of them, the position of the photovoltaic systems is conserved, and the power of the systems varies in 1%, 5%, 15%, 30% and 50% with respect to the MV/LV transformer rating. The network was simulated with OpenDSS in combination with Python, in order to dynamically evaluate the harmonic distortion.