{"title":"一种并网分布式发电系统防孤岛保护方案","authors":"A. Moallem, D. Yazdani, A. Bakhshai, P. Jain","doi":"10.1109/ICPCES.2010.5698662","DOIUrl":null,"url":null,"abstract":"This paper presents an active islanding detection method for grid-connected distributed power generation systems. The proposed scheme is based on an invasive current injection. An impedance estimation module in the frequency domain is introduced to estimate the equivalent impedance seen from the point of common coupling. To do so, a fast and accurate adaptive notch filter is used to extract the ambient components of the voltages and the currents. The accuracy of the proposed technique and its ability to detect islanding events even for purely resistive and nearly resonant loads are verified in this paper.","PeriodicalId":439893,"journal":{"name":"2010 International Conference on Power, Control and Embedded Systems","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"An anti-islanding protection scheme for grid-connected distributed power generation systems\",\"authors\":\"A. Moallem, D. Yazdani, A. Bakhshai, P. Jain\",\"doi\":\"10.1109/ICPCES.2010.5698662\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an active islanding detection method for grid-connected distributed power generation systems. The proposed scheme is based on an invasive current injection. An impedance estimation module in the frequency domain is introduced to estimate the equivalent impedance seen from the point of common coupling. To do so, a fast and accurate adaptive notch filter is used to extract the ambient components of the voltages and the currents. The accuracy of the proposed technique and its ability to detect islanding events even for purely resistive and nearly resonant loads are verified in this paper.\",\"PeriodicalId\":439893,\"journal\":{\"name\":\"2010 International Conference on Power, Control and Embedded Systems\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Power, Control and Embedded Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPCES.2010.5698662\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Power, Control and Embedded Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPCES.2010.5698662","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An anti-islanding protection scheme for grid-connected distributed power generation systems
This paper presents an active islanding detection method for grid-connected distributed power generation systems. The proposed scheme is based on an invasive current injection. An impedance estimation module in the frequency domain is introduced to estimate the equivalent impedance seen from the point of common coupling. To do so, a fast and accurate adaptive notch filter is used to extract the ambient components of the voltages and the currents. The accuracy of the proposed technique and its ability to detect islanding events even for purely resistive and nearly resonant loads are verified in this paper.