容错t型交叉连接源九电平逆变器

Vinay Kumar, Sanjeev Singh, Shailendra Jain
{"title":"容错t型交叉连接源九电平逆变器","authors":"Vinay Kumar, Sanjeev Singh, Shailendra Jain","doi":"10.1109/PIICON49524.2020.9113064","DOIUrl":null,"url":null,"abstract":"This paper presents a T-type cross connected sources nine level inverter with single open switch fault tolerant capability. Extra components and complex calculations are not required in the proposed fault tolerant method. The topology used has reduced voltage stress across switches, current and total harmonic distortion of voltage as compared to recent developed fault tolerant topologies. Phase opposition disposition sinusoidal pulse width modulation (POD-SPWM) scheme and nearest level control (NLC) is used to achieve high quality load voltage and current waveforms. MATLAB/Simulink simulation performance of the proposed fault-tolerant T-type cross connected source 9-level inverter is assessed through.","PeriodicalId":422853,"journal":{"name":"2020 IEEE 9th Power India International Conference (PIICON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Fault Tolerant T-Type Cross Connected Source Nine Level Inverter\",\"authors\":\"Vinay Kumar, Sanjeev Singh, Shailendra Jain\",\"doi\":\"10.1109/PIICON49524.2020.9113064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a T-type cross connected sources nine level inverter with single open switch fault tolerant capability. Extra components and complex calculations are not required in the proposed fault tolerant method. The topology used has reduced voltage stress across switches, current and total harmonic distortion of voltage as compared to recent developed fault tolerant topologies. Phase opposition disposition sinusoidal pulse width modulation (POD-SPWM) scheme and nearest level control (NLC) is used to achieve high quality load voltage and current waveforms. MATLAB/Simulink simulation performance of the proposed fault-tolerant T-type cross connected source 9-level inverter is assessed through.\",\"PeriodicalId\":422853,\"journal\":{\"name\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 9th Power India International Conference (PIICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIICON49524.2020.9113064\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 9th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIICON49524.2020.9113064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种具有单开开关容错能力的t型交叉连接源九电平逆变器。该方法不需要额外的组件和复杂的计算。与最近开发的容错拓扑结构相比,所使用的拓扑结构减少了开关间的电压应力、电流和电压的总谐波畸变。采用相对配置正弦脉宽调制(POD-SPWM)和最近电平控制(NLC)实现高质量的负载电压和电流波形。通过MATLAB/Simulink仿真对所提出的容错t型交叉连接源9电平逆变器的性能进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault Tolerant T-Type Cross Connected Source Nine Level Inverter
This paper presents a T-type cross connected sources nine level inverter with single open switch fault tolerant capability. Extra components and complex calculations are not required in the proposed fault tolerant method. The topology used has reduced voltage stress across switches, current and total harmonic distortion of voltage as compared to recent developed fault tolerant topologies. Phase opposition disposition sinusoidal pulse width modulation (POD-SPWM) scheme and nearest level control (NLC) is used to achieve high quality load voltage and current waveforms. MATLAB/Simulink simulation performance of the proposed fault-tolerant T-type cross connected source 9-level inverter is assessed through.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信