考虑正交电流引起的主电感偏差的矢量控制异步电动机转子电阻自适应

R. Ingruber, R. Seebacher, G. Dannerer
{"title":"考虑正交电流引起的主电感偏差的矢量控制异步电动机转子电阻自适应","authors":"R. Ingruber, R. Seebacher, G. Dannerer","doi":"10.1109/ICELMACH.2008.4800127","DOIUrl":null,"url":null,"abstract":"The vector control scheme for induction motors using the rotor flux reference frame is well known. To provide proper torque production, knowledge of the rotor time constant is essential. Many adaptation schemes have been presented using different paradigms. In this paper a scheme for rotor time constant adaptation is applied, which uses the difference between the measured and the calculated reactive power to calculate a correcting factor for the rotor time constant. Measurements have shown that the main inductance which is crucial to the calculation of the reactive power depends both on the magnetizing current and on the quadrature current. The adaptation scheme is therefore modified to consider this effect, improving the accuracy of torque production.","PeriodicalId":416125,"journal":{"name":"2008 18th International Conference on Electrical Machines","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rotor resistance adaptation for vector controlled induction motors considering deviations of the main inductance caused by the quadrature current\",\"authors\":\"R. Ingruber, R. Seebacher, G. Dannerer\",\"doi\":\"10.1109/ICELMACH.2008.4800127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The vector control scheme for induction motors using the rotor flux reference frame is well known. To provide proper torque production, knowledge of the rotor time constant is essential. Many adaptation schemes have been presented using different paradigms. In this paper a scheme for rotor time constant adaptation is applied, which uses the difference between the measured and the calculated reactive power to calculate a correcting factor for the rotor time constant. Measurements have shown that the main inductance which is crucial to the calculation of the reactive power depends both on the magnetizing current and on the quadrature current. The adaptation scheme is therefore modified to consider this effect, improving the accuracy of torque production.\",\"PeriodicalId\":416125,\"journal\":{\"name\":\"2008 18th International Conference on Electrical Machines\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 18th International Conference on Electrical Machines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2008.4800127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 18th International Conference on Electrical Machines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2008.4800127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用转子磁链参考系的异步电动机矢量控制方案是众所周知的。为了提供适当的扭矩生产,转子时间常数的知识是必不可少的。许多适应方案采用了不同的范式。本文提出了一种转子时间常数自适应方案,利用实测无功功率与计算无功功率的差值计算转子时间常数的修正系数。测量结果表明,对计算无功功率至关重要的主电感既取决于磁化电流,也取决于正交电流。因此,对自适应方案进行了修改,以考虑这种影响,提高了扭矩产生的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rotor resistance adaptation for vector controlled induction motors considering deviations of the main inductance caused by the quadrature current
The vector control scheme for induction motors using the rotor flux reference frame is well known. To provide proper torque production, knowledge of the rotor time constant is essential. Many adaptation schemes have been presented using different paradigms. In this paper a scheme for rotor time constant adaptation is applied, which uses the difference between the measured and the calculated reactive power to calculate a correcting factor for the rotor time constant. Measurements have shown that the main inductance which is crucial to the calculation of the reactive power depends both on the magnetizing current and on the quadrature current. The adaptation scheme is therefore modified to consider this effect, improving the accuracy of torque production.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信