{"title":"固态故障限流器发射角控制故障电流分析与控制","authors":"J. P. Sharma, Vibhor Chauhan","doi":"10.1109/ICESA.2015.7503405","DOIUrl":null,"url":null,"abstract":"In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.","PeriodicalId":259816,"journal":{"name":"2015 International Conference on Energy Systems and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Analysis and control of fault current by firing angle control of solid state fault current limiter\",\"authors\":\"J. P. Sharma, Vibhor Chauhan\",\"doi\":\"10.1109/ICESA.2015.7503405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.\",\"PeriodicalId\":259816,\"journal\":{\"name\":\"2015 International Conference on Energy Systems and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Energy Systems and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICESA.2015.7503405\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Energy Systems and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICESA.2015.7503405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis and control of fault current by firing angle control of solid state fault current limiter
In present scenario of power system, rapid development of power network increase fault current at a level that will affect the system security, stability and reliability. For many existing power system equipments of power system, fault current have exceeded from their withstand capacity. Hence, limiting the fault current to a safe level may reduce failure rate of power system equipment and maintenance cost of the system. This problem is greatly reduced by the use of solid state fault current limiter (SSFCL). The test system is a practical express distribution feeder, Bajaj hospital. In this paper, impacts of firing angle associated with SSFCL control system for symmetrical and unsymmetrical faults are investigated. From results, it is observed that increasing the firing angle leads a reduction in first peak of the fault current.