T. Jalakas, M. Jarkovoi, I. Roasto, J. Zakis, A. Garganeev
{"title":"电隔离qZS DC-DC变换器辐射发射特性研究","authors":"T. Jalakas, M. Jarkovoi, I. Roasto, J. Zakis, A. Garganeev","doi":"10.1109/POWERENG.2015.7266314","DOIUrl":null,"url":null,"abstract":"Ten different modulation methods of the isolated quasi Z-source inverter based DC-DC converter were tested to find out radiated emission levels. EMC measurements were performed on a low power 250 W prototype. A radiated emission test was carried out in a GTEM cell (gigahertz transverse electromagnetic cell) according to the EMC standard IEC 61000-4-20. To obtain a complete overview of the emissions, both C and D bands were included in a single test at the start and stop frequencies 30 MHz and 1 GHz, respectively. Measuring bandwidth of 120 kHz with a 6 dB EMI filter was used.","PeriodicalId":334135,"journal":{"name":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","volume":"149 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Investigation of radiated emissions of a galvanically isolated qZS DC-DC converter\",\"authors\":\"T. Jalakas, M. Jarkovoi, I. Roasto, J. Zakis, A. Garganeev\",\"doi\":\"10.1109/POWERENG.2015.7266314\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ten different modulation methods of the isolated quasi Z-source inverter based DC-DC converter were tested to find out radiated emission levels. EMC measurements were performed on a low power 250 W prototype. A radiated emission test was carried out in a GTEM cell (gigahertz transverse electromagnetic cell) according to the EMC standard IEC 61000-4-20. To obtain a complete overview of the emissions, both C and D bands were included in a single test at the start and stop frequencies 30 MHz and 1 GHz, respectively. Measuring bandwidth of 120 kHz with a 6 dB EMI filter was used.\",\"PeriodicalId\":334135,\"journal\":{\"name\":\"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)\",\"volume\":\"149 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2015.7266314\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2015.7266314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of radiated emissions of a galvanically isolated qZS DC-DC converter
Ten different modulation methods of the isolated quasi Z-source inverter based DC-DC converter were tested to find out radiated emission levels. EMC measurements were performed on a low power 250 W prototype. A radiated emission test was carried out in a GTEM cell (gigahertz transverse electromagnetic cell) according to the EMC standard IEC 61000-4-20. To obtain a complete overview of the emissions, both C and D bands were included in a single test at the start and stop frequencies 30 MHz and 1 GHz, respectively. Measuring bandwidth of 120 kHz with a 6 dB EMI filter was used.