用于pv -电池混合能源系统的双输出电源管理单元

A. Rezk, A. Helmy, Y. Ismail
{"title":"用于pv -电池混合能源系统的双输出电源管理单元","authors":"A. Rezk, A. Helmy, Y. Ismail","doi":"10.1109/ICEAC.2015.7352202","DOIUrl":null,"url":null,"abstract":"This paper presents a novel power management unit for PV-battery hybrid systems. The proposed unit tracks the PV cells' Maximum Power Point (MPP), distributes the power among dual loads, and handles any surplus or deficit power by a battery. A digital controller has been realized using VHDL, and downloaded on an FPGA to manage a novel single inductor Dual Input Multiple Output DC-DC converter. A prototype has been implemented, tested, and verified under varying light intensities. The experiments have showed that for a sampling time of 5ms, both MPP tracking and dual load regulation can be accomplished within 300ms and 0.1V error.","PeriodicalId":334594,"journal":{"name":"5th International Conference on Energy Aware Computing Systems & Applications","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dual output power management unit for a PV-battery hybrid energy system\",\"authors\":\"A. Rezk, A. Helmy, Y. Ismail\",\"doi\":\"10.1109/ICEAC.2015.7352202\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel power management unit for PV-battery hybrid systems. The proposed unit tracks the PV cells' Maximum Power Point (MPP), distributes the power among dual loads, and handles any surplus or deficit power by a battery. A digital controller has been realized using VHDL, and downloaded on an FPGA to manage a novel single inductor Dual Input Multiple Output DC-DC converter. A prototype has been implemented, tested, and verified under varying light intensities. The experiments have showed that for a sampling time of 5ms, both MPP tracking and dual load regulation can be accomplished within 300ms and 0.1V error.\",\"PeriodicalId\":334594,\"journal\":{\"name\":\"5th International Conference on Energy Aware Computing Systems & Applications\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"5th International Conference on Energy Aware Computing Systems & Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEAC.2015.7352202\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"5th International Conference on Energy Aware Computing Systems & Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAC.2015.7352202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种新型的光伏-电池混合动力系统电源管理单元。该装置跟踪光伏电池的最大功率点(MPP),在双负载之间分配电力,并处理电池的任何剩余或不足电力。利用VHDL实现了一种数字控制器,并将其下载到FPGA上,用于管理新型单电感双输入多输出DC-DC变换器。一个原型已经在不同的光强度下实现、测试和验证。实验表明,在5ms的采样时间内,MPP跟踪和双负载调节均可在300ms和0.1V误差范围内完成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual output power management unit for a PV-battery hybrid energy system
This paper presents a novel power management unit for PV-battery hybrid systems. The proposed unit tracks the PV cells' Maximum Power Point (MPP), distributes the power among dual loads, and handles any surplus or deficit power by a battery. A digital controller has been realized using VHDL, and downloaded on an FPGA to manage a novel single inductor Dual Input Multiple Output DC-DC converter. A prototype has been implemented, tested, and verified under varying light intensities. The experiments have showed that for a sampling time of 5ms, both MPP tracking and dual load regulation can be accomplished within 300ms and 0.1V error.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信