瞳孔测量法检测警觉性

L. McIntire, J. McIntire, R. McKinley, C. Goodyear
{"title":"瞳孔测量法检测警觉性","authors":"L. McIntire, J. McIntire, R. McKinley, C. Goodyear","doi":"10.1145/2578153.2578177","DOIUrl":null,"url":null,"abstract":"Sustained attention (vigilance) is required for many professions such as air traffic controllers, imagery analysts, airport security screeners, and cyber operators. A lapse in attention in any of these environments can have deadly consequences. The purpose of this study was to determine the ability of pupillometry to detect changes in vigilance performance. Each participant performed a 40-minute vigilance task while wearing an eye-tracker on each of four separate days. Pupil diameter, pupil eccentricity, and pupil velocity all changed significantly over time (p<.05) during the task. Significant correlations indicate that all metrics increased as vigilance performance declined except for pupil diameter, which decreased and the pupil became miotic. These results are consistent with other research on attention, fatigue, and arousal levels. Using an eye-tracker to detect changes in pupillometry in an operational environment would allow interventions to be implemented.","PeriodicalId":142459,"journal":{"name":"Proceedings of the Symposium on Eye Tracking Research and Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Detection of vigilance performance with pupillometry\",\"authors\":\"L. McIntire, J. McIntire, R. McKinley, C. Goodyear\",\"doi\":\"10.1145/2578153.2578177\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sustained attention (vigilance) is required for many professions such as air traffic controllers, imagery analysts, airport security screeners, and cyber operators. A lapse in attention in any of these environments can have deadly consequences. The purpose of this study was to determine the ability of pupillometry to detect changes in vigilance performance. Each participant performed a 40-minute vigilance task while wearing an eye-tracker on each of four separate days. Pupil diameter, pupil eccentricity, and pupil velocity all changed significantly over time (p<.05) during the task. Significant correlations indicate that all metrics increased as vigilance performance declined except for pupil diameter, which decreased and the pupil became miotic. These results are consistent with other research on attention, fatigue, and arousal levels. Using an eye-tracker to detect changes in pupillometry in an operational environment would allow interventions to be implemented.\",\"PeriodicalId\":142459,\"journal\":{\"name\":\"Proceedings of the Symposium on Eye Tracking Research and Applications\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Symposium on Eye Tracking Research and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2578153.2578177\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Symposium on Eye Tracking Research and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2578153.2578177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

许多职业都需要持续的关注(警惕),如空中交通管制员、图像分析师、机场安检人员和网络操作员。在这些环境中,注意力的疏忽可能会造成致命的后果。本研究的目的是确定瞳孔测量法检测警觉性表现变化的能力。每个参与者在四天内分别戴着眼动仪进行40分钟的警惕性任务。在实验过程中,瞳孔直径、瞳孔偏心率和瞳孔速度均随时间发生显著变化(p< 0.05)。显著相关性表明,除了瞳孔直径减小和瞳孔缩小外,所有指标都随着警觉性的下降而增加。这些结果与其他关于注意力、疲劳和觉醒水平的研究一致。在操作环境中使用眼动仪来检测瞳孔测量的变化将允许实施干预。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detection of vigilance performance with pupillometry
Sustained attention (vigilance) is required for many professions such as air traffic controllers, imagery analysts, airport security screeners, and cyber operators. A lapse in attention in any of these environments can have deadly consequences. The purpose of this study was to determine the ability of pupillometry to detect changes in vigilance performance. Each participant performed a 40-minute vigilance task while wearing an eye-tracker on each of four separate days. Pupil diameter, pupil eccentricity, and pupil velocity all changed significantly over time (p<.05) during the task. Significant correlations indicate that all metrics increased as vigilance performance declined except for pupil diameter, which decreased and the pupil became miotic. These results are consistent with other research on attention, fatigue, and arousal levels. Using an eye-tracker to detect changes in pupillometry in an operational environment would allow interventions to be implemented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信