{"title":"在马的气管内管的近端和远端测量的潮汐末氟烷浓度的比较。","authors":"N S Matthews,&nbsp;S M Hartsfield,&nbsp;J L Cornick,&nbsp;J D Jacobson,&nbsp;J D Williams","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Measurements (n = 126) of end-tidal halothane concentrations were taken from 21 horses anesthetized for routine and emergency surgery. One hundred five paired values allowed comparison of gas samples taken near the oral end of the endotracheal tube (Y1) to samples obtained at the cuffed end of the endotracheal tube (Y2). Twenty-one paired readings were assessed to compare samples taken 25 cm beyond the cuffed end of the tube (Y3) to samples from Y1. Measurements were made at all locations at 15-minute intervals starting 30 minutes after beginning halothane. All measurements were made in triplicate at end-expiration, and both sites were sampled within 1 minute of each other. Halothane concentration was measured by rapid infrared analysis with a gas sampling rate of 150 ml/min and displayed as a digital reading. Calibration of the machine was checked regularly. The difference between readings (Y1-Y2 or Y1-Y3 = Sdif) was tested using general linear models and a significance level of p less than 0.05 was used. The variable Sdif was analyzed with respect to time, mode of ventilation, and type of recumbency; no effects of these variables were detected. The mean values (+/- SD) of 105 readings for Y1 and Y2 were 2.41 vol% (+/- 0.49) and 2.39 vol% (+/- 0.49) respectively, and the Pearson's correlation coefficient (Y1 vs Y2) was 0.96. The mean values (+/- SD) of 21 measurements for Y1 and Y3 were 2.31 vol% (+/- 0.27) and 2.32 vol% (+/- 0.28) respectively and the Pearson's correlation coefficient (Y1 vs Y3) was 0.98.</p>","PeriodicalId":22466,"journal":{"name":"The Cornell veterinarian","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of end-tidal halothane concentrations measured at proximal and distal ends of the endotracheal tube in the horse.\",\"authors\":\"N S Matthews,&nbsp;S M Hartsfield,&nbsp;J L Cornick,&nbsp;J D Jacobson,&nbsp;J D Williams\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Measurements (n = 126) of end-tidal halothane concentrations were taken from 21 horses anesthetized for routine and emergency surgery. One hundred five paired values allowed comparison of gas samples taken near the oral end of the endotracheal tube (Y1) to samples obtained at the cuffed end of the endotracheal tube (Y2). Twenty-one paired readings were assessed to compare samples taken 25 cm beyond the cuffed end of the tube (Y3) to samples from Y1. Measurements were made at all locations at 15-minute intervals starting 30 minutes after beginning halothane. All measurements were made in triplicate at end-expiration, and both sites were sampled within 1 minute of each other. Halothane concentration was measured by rapid infrared analysis with a gas sampling rate of 150 ml/min and displayed as a digital reading. Calibration of the machine was checked regularly. The difference between readings (Y1-Y2 or Y1-Y3 = Sdif) was tested using general linear models and a significance level of p less than 0.05 was used. The variable Sdif was analyzed with respect to time, mode of ventilation, and type of recumbency; no effects of these variables were detected. The mean values (+/- SD) of 105 readings for Y1 and Y2 were 2.41 vol% (+/- 0.49) and 2.39 vol% (+/- 0.49) respectively, and the Pearson's correlation coefficient (Y1 vs Y2) was 0.96. The mean values (+/- SD) of 21 measurements for Y1 and Y3 were 2.31 vol% (+/- 0.27) and 2.32 vol% (+/- 0.28) respectively and the Pearson's correlation coefficient (Y1 vs Y3) was 0.98.</p>\",\"PeriodicalId\":22466,\"journal\":{\"name\":\"The Cornell veterinarian\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Cornell veterinarian\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Cornell veterinarian","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对21匹因常规和紧急手术麻醉的马进行潮汐末氟烷浓度测量(n = 126)。105个配对值允许在气管插管口端(Y1)附近采集的气体样本与在气管插管口端(Y2)获得的样本进行比较。评估21个配对读数,以比较试管(Y3)外25厘米处的样本与Y1的样本。在氟烷开始后30分钟开始,每隔15分钟在所有地点进行测量。所有的测量都在结束时进行了三次,两个地点在1分钟内采样。采用快速红外分析测量氟烷浓度,气体采样速率为150 ml/min,并以数字读数显示。定期检查机器的校准。读数之间的差异(Y1-Y2或Y1-Y3 = Sdif)使用一般线性模型进行检验,并使用p < 0.05的显著性水平。分析变量Sdif与时间、通风方式和卧位类型的关系;没有检测到这些变量的影响。Y1和Y2 105个读数的平均值(+/- SD)分别为2.41 vol%(+/- 0.49)和2.39 vol% (+/- 0.49), Pearson相关系数(Y1 vs Y2)为0.96。Y1和Y3的21个测量值的平均值(+/- SD)分别为2.31 vol%(+/- 0.27)和2.32 vol% (+/- 0.28), Pearson相关系数(Y1 vs Y3)为0.98。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A comparison of end-tidal halothane concentrations measured at proximal and distal ends of the endotracheal tube in the horse.

Measurements (n = 126) of end-tidal halothane concentrations were taken from 21 horses anesthetized for routine and emergency surgery. One hundred five paired values allowed comparison of gas samples taken near the oral end of the endotracheal tube (Y1) to samples obtained at the cuffed end of the endotracheal tube (Y2). Twenty-one paired readings were assessed to compare samples taken 25 cm beyond the cuffed end of the tube (Y3) to samples from Y1. Measurements were made at all locations at 15-minute intervals starting 30 minutes after beginning halothane. All measurements were made in triplicate at end-expiration, and both sites were sampled within 1 minute of each other. Halothane concentration was measured by rapid infrared analysis with a gas sampling rate of 150 ml/min and displayed as a digital reading. Calibration of the machine was checked regularly. The difference between readings (Y1-Y2 or Y1-Y3 = Sdif) was tested using general linear models and a significance level of p less than 0.05 was used. The variable Sdif was analyzed with respect to time, mode of ventilation, and type of recumbency; no effects of these variables were detected. The mean values (+/- SD) of 105 readings for Y1 and Y2 were 2.41 vol% (+/- 0.49) and 2.39 vol% (+/- 0.49) respectively, and the Pearson's correlation coefficient (Y1 vs Y2) was 0.96. The mean values (+/- SD) of 21 measurements for Y1 and Y3 were 2.31 vol% (+/- 0.27) and 2.32 vol% (+/- 0.28) respectively and the Pearson's correlation coefficient (Y1 vs Y3) was 0.98.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信