输电线路故障对动态电压稳定性的影响

M. Yalçin, M. Turan, Z. Demir
{"title":"输电线路故障对动态电压稳定性的影响","authors":"M. Yalçin, M. Turan, Z. Demir","doi":"10.1109/PTC.1999.826511","DOIUrl":null,"url":null,"abstract":"In recent years, there has been an increasing interest for the analysis of dynamic voltage stability on power systems. It is well known that induction motor loads have a particularly hazardous role in the voltage stability. On the other hand, in transmission systems loaded by induction motor loads, configuration changes such as line tripping, may cause voltage collapse. Moreover, if there is a fault on transmission lines, the disturbance effect will then significantly increase the possibility of voltage collapse. In this study, a transmission system subjected to different faults on different locations is examined from the viewpoint of voltage stability. The study shows that in the certain cases of paralleled transmission lines, single or double phase tripping of a faulted line will have positive effects on voltage stability, instead of all three phase tripping.","PeriodicalId":101688,"journal":{"name":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Effects of transmission line faults on dynamic voltage stability\",\"authors\":\"M. Yalçin, M. Turan, Z. Demir\",\"doi\":\"10.1109/PTC.1999.826511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, there has been an increasing interest for the analysis of dynamic voltage stability on power systems. It is well known that induction motor loads have a particularly hazardous role in the voltage stability. On the other hand, in transmission systems loaded by induction motor loads, configuration changes such as line tripping, may cause voltage collapse. Moreover, if there is a fault on transmission lines, the disturbance effect will then significantly increase the possibility of voltage collapse. In this study, a transmission system subjected to different faults on different locations is examined from the viewpoint of voltage stability. The study shows that in the certain cases of paralleled transmission lines, single or double phase tripping of a faulted line will have positive effects on voltage stability, instead of all three phase tripping.\",\"PeriodicalId\":101688,\"journal\":{\"name\":\"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PTC.1999.826511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.1999.826511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

近年来,人们对电力系统动态电压稳定性的分析越来越感兴趣。众所周知,感应电机负载在电压稳定性中具有特别危险的作用。另一方面,在由感应电机负载的输电系统中,线路跳闸等配置变化可能导致电压崩溃。此外,如果输电线路出现故障,那么扰动效应将大大增加电压崩溃的可能性。本文从电压稳定性的角度研究了在不同位置发生不同故障的输电系统。研究表明,在并联输电线路的某些情况下,故障线路的单相脱扣或双相脱扣将对电压稳定性产生积极影响,而不是全部三相脱扣。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of transmission line faults on dynamic voltage stability
In recent years, there has been an increasing interest for the analysis of dynamic voltage stability on power systems. It is well known that induction motor loads have a particularly hazardous role in the voltage stability. On the other hand, in transmission systems loaded by induction motor loads, configuration changes such as line tripping, may cause voltage collapse. Moreover, if there is a fault on transmission lines, the disturbance effect will then significantly increase the possibility of voltage collapse. In this study, a transmission system subjected to different faults on different locations is examined from the viewpoint of voltage stability. The study shows that in the certain cases of paralleled transmission lines, single or double phase tripping of a faulted line will have positive effects on voltage stability, instead of all three phase tripping.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信