{"title":"EKC265熔池寿命及焊垫氟碳污染的研究","authors":"L. An, K. Lai, W. Chay, Y. Hua","doi":"10.1109/SMELEC.1998.781140","DOIUrl":null,"url":null,"abstract":"A study was conducted on EKC265 cleaning bath life. The Auger analysis technique was used to evaluate the contamination levels of fluorine and carbon on the bond pad after the EKC265 process. The results showed that it is necessary and effective to perform EKC265 cleaning for L95 lots. The contamination levels of C and F on the surface (0 /spl Aring/) of bond pads were about 20 at% and 7.5 at% at the bath life of 40 lots used currently. However, they were 0 at.% at a depth of 50 /spl Aring/. The results also show that it is possible to extend EKC265 bath life from 40 lots (6 inch) to 50 lots (6 inch) for cost reduction purposes.","PeriodicalId":356206,"journal":{"name":"ICSE'98. 1998 IEEE International Conference on Semiconductor Electronics. Proceedings (Cat. No.98EX187)","volume":"160 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A study on EKC265 bath life and fluorine and carbon contamination on bond pads\",\"authors\":\"L. An, K. Lai, W. Chay, Y. Hua\",\"doi\":\"10.1109/SMELEC.1998.781140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A study was conducted on EKC265 cleaning bath life. The Auger analysis technique was used to evaluate the contamination levels of fluorine and carbon on the bond pad after the EKC265 process. The results showed that it is necessary and effective to perform EKC265 cleaning for L95 lots. The contamination levels of C and F on the surface (0 /spl Aring/) of bond pads were about 20 at% and 7.5 at% at the bath life of 40 lots used currently. However, they were 0 at.% at a depth of 50 /spl Aring/. The results also show that it is possible to extend EKC265 bath life from 40 lots (6 inch) to 50 lots (6 inch) for cost reduction purposes.\",\"PeriodicalId\":356206,\"journal\":{\"name\":\"ICSE'98. 1998 IEEE International Conference on Semiconductor Electronics. Proceedings (Cat. No.98EX187)\",\"volume\":\"160 3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICSE'98. 1998 IEEE International Conference on Semiconductor Electronics. Proceedings (Cat. No.98EX187)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SMELEC.1998.781140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSE'98. 1998 IEEE International Conference on Semiconductor Electronics. Proceedings (Cat. No.98EX187)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SMELEC.1998.781140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

对EKC265清洗浴寿命进行了研究。采用俄歇分析技术对EKC265工艺后粘结垫的氟、碳污染程度进行了评价。结果表明,对L95批次进行EKC265清洗是必要且有效的。目前使用的40批粘结垫表面(0 /spl Aring/)的C和F污染水平分别为20 %和7.5 %。然而,他们都是0。%,深度为50 /spl。结果还表明,为了降低成本,可以将EKC265的浴槽寿命从40批次(6英寸)延长到50批次(6英寸)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study on EKC265 bath life and fluorine and carbon contamination on bond pads
A study was conducted on EKC265 cleaning bath life. The Auger analysis technique was used to evaluate the contamination levels of fluorine and carbon on the bond pad after the EKC265 process. The results showed that it is necessary and effective to perform EKC265 cleaning for L95 lots. The contamination levels of C and F on the surface (0 /spl Aring/) of bond pads were about 20 at% and 7.5 at% at the bath life of 40 lots used currently. However, they were 0 at.% at a depth of 50 /spl Aring/. The results also show that it is possible to extend EKC265 bath life from 40 lots (6 inch) to 50 lots (6 inch) for cost reduction purposes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信