{"title":"基于实时混合模拟器的广域阻尼控制器-硬件在环仿真设置","authors":"K. Gajjar, Kapil Chauhan, A. Kulkarni","doi":"10.1109/NPSC57038.2022.10069003","DOIUrl":null,"url":null,"abstract":"Poorly damped low-frequency inter-area electro-mechanical oscillations are a major concern in large synchronous grids. Embedded power electronic actuators such as HVDC and FACTS devices with wide-area damping controllers (WADCs) can be an effective solution to this problem. A WADC uses the synchrophasor measurements from the phasor measurement units (PMUs) installed across the system. This paper illustrates the controller-hardware-in-the-loop (CHIL) simulation setup for testing a WADC using a real-time hybrid simulator (RTHS). The RTHS does real-time co-simulation using a transient stability program (TSAT) and a real-time simulator that simulates electromagnetic transients. A two-area four-machine test system with an embedded HVDC link is used for demonstration.","PeriodicalId":162808,"journal":{"name":"2022 22nd National Power Systems Conference (NPSC)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Controller-Hardware-in-the-Loop Simulation Setup using a Real-Time Hybrid Simulator for Testing of Wide-area Damping Controllers\",\"authors\":\"K. Gajjar, Kapil Chauhan, A. Kulkarni\",\"doi\":\"10.1109/NPSC57038.2022.10069003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Poorly damped low-frequency inter-area electro-mechanical oscillations are a major concern in large synchronous grids. Embedded power electronic actuators such as HVDC and FACTS devices with wide-area damping controllers (WADCs) can be an effective solution to this problem. A WADC uses the synchrophasor measurements from the phasor measurement units (PMUs) installed across the system. This paper illustrates the controller-hardware-in-the-loop (CHIL) simulation setup for testing a WADC using a real-time hybrid simulator (RTHS). The RTHS does real-time co-simulation using a transient stability program (TSAT) and a real-time simulator that simulates electromagnetic transients. A two-area four-machine test system with an embedded HVDC link is used for demonstration.\",\"PeriodicalId\":162808,\"journal\":{\"name\":\"2022 22nd National Power Systems Conference (NPSC)\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 22nd National Power Systems Conference (NPSC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NPSC57038.2022.10069003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 22nd National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC57038.2022.10069003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

低阻尼低频区域间机电振荡是大型同步电网的主要问题。嵌入式电力电子执行器,如具有广域阻尼控制器(wadc)的HVDC和FACTS设备,可以有效地解决这一问题。WADC使用安装在整个系统中的相量测量单元(pmu)的同步相量测量。本文介绍了使用实时混合模拟器(RTHS)测试WADC的控制器-硬件在环(CHIL)仿真设置。RTHS使用瞬态稳定程序(TSAT)和模拟电磁瞬变的实时模拟器进行实时联合仿真。采用嵌入式高压直流链路的两区四机测试系统进行演示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Controller-Hardware-in-the-Loop Simulation Setup using a Real-Time Hybrid Simulator for Testing of Wide-area Damping Controllers
Poorly damped low-frequency inter-area electro-mechanical oscillations are a major concern in large synchronous grids. Embedded power electronic actuators such as HVDC and FACTS devices with wide-area damping controllers (WADCs) can be an effective solution to this problem. A WADC uses the synchrophasor measurements from the phasor measurement units (PMUs) installed across the system. This paper illustrates the controller-hardware-in-the-loop (CHIL) simulation setup for testing a WADC using a real-time hybrid simulator (RTHS). The RTHS does real-time co-simulation using a transient stability program (TSAT) and a real-time simulator that simulates electromagnetic transients. A two-area four-machine test system with an embedded HVDC link is used for demonstration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信