{"title":"分散发电配电网暂态稳定性分析","authors":"A. Ishchenko, J. Myrzik, W. Kling","doi":"10.1109/UPEC.2006.367749","DOIUrl":null,"url":null,"abstract":"In this paper transient stability of an existing 10 kV distribution network with combined heat and power plants, microturbinesand wind turbines is analyzed. In order to do this, dynamic models of the network and generators have been created and simulations for faults at different network locations have been done. From the analysis it appears that the most critical parameter, which influences transient stability in the test network, is the inertia of a microturbine. Simulations have shown that there is linear relationship between inertia constant of microturbine and critical clearing time. After that it has been checked that the protection of DG satisfies transient stability requirements. In the end, the possibility for providing DG support to the network during and after disturbances using fault ride-through concept has been considered and simulations illustrate that DG protection can guarantee transient stability in this case as well.","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Transient Stability Analysis of Distribution Network with Dispersed Generation\",\"authors\":\"A. Ishchenko, J. Myrzik, W. Kling\",\"doi\":\"10.1109/UPEC.2006.367749\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper transient stability of an existing 10 kV distribution network with combined heat and power plants, microturbinesand wind turbines is analyzed. In order to do this, dynamic models of the network and generators have been created and simulations for faults at different network locations have been done. From the analysis it appears that the most critical parameter, which influences transient stability in the test network, is the inertia of a microturbine. Simulations have shown that there is linear relationship between inertia constant of microturbine and critical clearing time. After that it has been checked that the protection of DG satisfies transient stability requirements. In the end, the possibility for providing DG support to the network during and after disturbances using fault ride-through concept has been considered and simulations illustrate that DG protection can guarantee transient stability in this case as well.\",\"PeriodicalId\":184186,\"journal\":{\"name\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 41st International Universities Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2006.367749\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

本文分析了现有10kv热电联产配电网的暂态稳定性。为此,建立了电网和发电机的动态模型,并对不同网络位置的故障进行了仿真。分析表明,影响试验网暂态稳定的最关键参数是微水轮机的惯量。仿真结果表明,微涡轮惯性常数与临界清流时间呈线性关系。然后检查DG的保护是否满足暂态稳定要求。最后,考虑了在干扰期间和之后使用故障穿越概念为网络提供DG支持的可能性,仿真表明DG保护在这种情况下也可以保证暂态稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient Stability Analysis of Distribution Network with Dispersed Generation
In this paper transient stability of an existing 10 kV distribution network with combined heat and power plants, microturbinesand wind turbines is analyzed. In order to do this, dynamic models of the network and generators have been created and simulations for faults at different network locations have been done. From the analysis it appears that the most critical parameter, which influences transient stability in the test network, is the inertia of a microturbine. Simulations have shown that there is linear relationship between inertia constant of microturbine and critical clearing time. After that it has been checked that the protection of DG satisfies transient stability requirements. In the end, the possibility for providing DG support to the network during and after disturbances using fault ride-through concept has been considered and simulations illustrate that DG protection can guarantee transient stability in this case as well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信