Gerardo Escobar, A. Valdez, R. Torres-Olguin, M. Martínez-Montejano
{"title":"具有中性线电流补偿的三相四线并联有源滤波器的基于模型的控制器","authors":"Gerardo Escobar, A. Valdez, R. Torres-Olguin, M. Martínez-Montejano","doi":"10.1109/ciep.2006.312127","DOIUrl":null,"url":null,"abstract":"This paper presents a model-based controller for a three-phase four-wire shunt active filter, which uses a three-leg split-capacitor topology to implement the voltage source inverter. The controller is aimed to compensate reactive power and harmonic distortion in the general case of distorted and unbalanced source voltages and load currents, including distorting loads connected between a phase and the neutral line. In addition, the controller is able to compensate for the homopolar component of the load current, that is, the current flowing to the source via the neutral line can be considerably reduced without modifying the actual topology. The complete model in (fixed frame) alphabetagamma-coordinates is presented. Special attention is given to the homopolar component (referred here as the gamma-component) of the line current, source voltage and control input, which are instrumental for the control design purpose. Experimental results in a 2 kVA prototype are provided to illustrate the benefits of the proposed solution","PeriodicalId":131301,"journal":{"name":"2006 IEEE International Power Electronics Congress","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"A model-based controller for a three-phase four-wire shunt active filter with compensation of the neutral line current\",\"authors\":\"Gerardo Escobar, A. Valdez, R. Torres-Olguin, M. Martínez-Montejano\",\"doi\":\"10.1109/ciep.2006.312127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a model-based controller for a three-phase four-wire shunt active filter, which uses a three-leg split-capacitor topology to implement the voltage source inverter. The controller is aimed to compensate reactive power and harmonic distortion in the general case of distorted and unbalanced source voltages and load currents, including distorting loads connected between a phase and the neutral line. In addition, the controller is able to compensate for the homopolar component of the load current, that is, the current flowing to the source via the neutral line can be considerably reduced without modifying the actual topology. The complete model in (fixed frame) alphabetagamma-coordinates is presented. Special attention is given to the homopolar component (referred here as the gamma-component) of the line current, source voltage and control input, which are instrumental for the control design purpose. Experimental results in a 2 kVA prototype are provided to illustrate the benefits of the proposed solution\",\"PeriodicalId\":131301,\"journal\":{\"name\":\"2006 IEEE International Power Electronics Congress\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Power Electronics Congress\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ciep.2006.312127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Power Electronics Congress","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ciep.2006.312127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A model-based controller for a three-phase four-wire shunt active filter with compensation of the neutral line current
This paper presents a model-based controller for a three-phase four-wire shunt active filter, which uses a three-leg split-capacitor topology to implement the voltage source inverter. The controller is aimed to compensate reactive power and harmonic distortion in the general case of distorted and unbalanced source voltages and load currents, including distorting loads connected between a phase and the neutral line. In addition, the controller is able to compensate for the homopolar component of the load current, that is, the current flowing to the source via the neutral line can be considerably reduced without modifying the actual topology. The complete model in (fixed frame) alphabetagamma-coordinates is presented. Special attention is given to the homopolar component (referred here as the gamma-component) of the line current, source voltage and control input, which are instrumental for the control design purpose. Experimental results in a 2 kVA prototype are provided to illustrate the benefits of the proposed solution