低pH混凝土的配方与表征

M. Codina, C. Cau-dit-Coumes, J. Verdier, Patrick Le Bescop
{"title":"低pH混凝土的配方与表征","authors":"M. Codina, C. Cau-dit-Coumes, J. Verdier, Patrick Le Bescop","doi":"10.1080/17747120.2007.9692937","DOIUrl":null,"url":null,"abstract":"ABSTRACT Investigations were carried out to formulate and characterize low-alkalinity and low-heat cements which would be compatible with an underground waste repository environment. Pozzolans (high-silica product such as fly ash and silica fume) and blast furnace slag were added to Portland cement to decrease the cement pore solution pH to 11. The alkali content of the interstitial solution (≈ 1 to 5 mmol/L) of blend was strongly reduced which decreased the pH by more than one unity as compared with control samples. The blends exhibited a low heat output (temperature rise below 20°C). The prepared concrete specimens had a compressive strength higher than 70 MPa after one year of curing in 100% RH, a low shrinkage (−350 to −500μm/m) and it was possible to prepare workable concrete despite the very high amounts of pozzolans in the blends.","PeriodicalId":368904,"journal":{"name":"Revue Européenne de Génie Civil","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Formulation et caractérisation de bétons bas pH\",\"authors\":\"M. Codina, C. Cau-dit-Coumes, J. Verdier, Patrick Le Bescop\",\"doi\":\"10.1080/17747120.2007.9692937\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Investigations were carried out to formulate and characterize low-alkalinity and low-heat cements which would be compatible with an underground waste repository environment. Pozzolans (high-silica product such as fly ash and silica fume) and blast furnace slag were added to Portland cement to decrease the cement pore solution pH to 11. The alkali content of the interstitial solution (≈ 1 to 5 mmol/L) of blend was strongly reduced which decreased the pH by more than one unity as compared with control samples. The blends exhibited a low heat output (temperature rise below 20°C). The prepared concrete specimens had a compressive strength higher than 70 MPa after one year of curing in 100% RH, a low shrinkage (−350 to −500μm/m) and it was possible to prepare workable concrete despite the very high amounts of pozzolans in the blends.\",\"PeriodicalId\":368904,\"journal\":{\"name\":\"Revue Européenne de Génie Civil\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revue Européenne de Génie Civil\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/17747120.2007.9692937\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revue Européenne de Génie Civil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17747120.2007.9692937","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

摘要研究了与地下废物处置环境相适应的低碱度、低热水泥的配方和性能。在硅酸盐水泥中加入火山灰(高硅产物,如粉煤灰和硅灰)和高炉矿渣,使水泥孔隙溶液pH值降至11。混合物的间隙液(≈1 ~ 5 mmol/L)的碱含量明显降低,pH值比对照样品降低了1个以上。共混物表现出低热量输出(温度上升低于20°C)。在100%相对湿度下养护1年后,所制备的混凝土试件抗压强度高于70 MPa,收缩率低(- 350 ~ - 500μm/m),尽管混合料中含有大量的火山灰,但仍有可能制备出可使用的混凝土。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Formulation et caractérisation de bétons bas pH
ABSTRACT Investigations were carried out to formulate and characterize low-alkalinity and low-heat cements which would be compatible with an underground waste repository environment. Pozzolans (high-silica product such as fly ash and silica fume) and blast furnace slag were added to Portland cement to decrease the cement pore solution pH to 11. The alkali content of the interstitial solution (≈ 1 to 5 mmol/L) of blend was strongly reduced which decreased the pH by more than one unity as compared with control samples. The blends exhibited a low heat output (temperature rise below 20°C). The prepared concrete specimens had a compressive strength higher than 70 MPa after one year of curing in 100% RH, a low shrinkage (−350 to −500μm/m) and it was possible to prepare workable concrete despite the very high amounts of pozzolans in the blends.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信