室内医疗环境超宽带定位实现亚毫米精度

M. Mahfouz, M. Kuhn, Yazhou Wang, J. Turnmire, A. Fathy
{"title":"室内医疗环境超宽带定位实现亚毫米精度","authors":"M. Mahfouz, M. Kuhn, Yazhou Wang, J. Turnmire, A. Fathy","doi":"10.1109/BIOWIRELESS.2011.5724360","DOIUrl":null,"url":null,"abstract":"Ultra wideband (UWB) positioning systems are increasingly used in indoor environments since commercial systems can provide 3-D accuracy of a few centimeters. Many applications exist in medicine for UWB positioning which includes tracking personnel, assets, and surgical navigation. We have designed a UWB positioning system with millimeter accuracy. Certain applications, including surgical navigation, have even more stringent accuracy requirements in the sub-millimeter range. Many challenges must be overcome to achieve sub-millimeter accuracy including indoor multipath interference, system clock jitter and drift, local oscillator phase noise, sampling-rate limitations, and phase center error. This paper discusses sub-millimeter accuracy in UWB positioning for medical applications and outlines key challenges faced in achieving it with our UWB positioning system. Solutions to these challenges are also outlined followed by a discussion of future work needed to integrate the entire system.","PeriodicalId":430449,"journal":{"name":"2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems","volume":"92 32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Towards sub-millimeter accuracy in UWB positioning for indoor medical environments\",\"authors\":\"M. Mahfouz, M. Kuhn, Yazhou Wang, J. Turnmire, A. Fathy\",\"doi\":\"10.1109/BIOWIRELESS.2011.5724360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ultra wideband (UWB) positioning systems are increasingly used in indoor environments since commercial systems can provide 3-D accuracy of a few centimeters. Many applications exist in medicine for UWB positioning which includes tracking personnel, assets, and surgical navigation. We have designed a UWB positioning system with millimeter accuracy. Certain applications, including surgical navigation, have even more stringent accuracy requirements in the sub-millimeter range. Many challenges must be overcome to achieve sub-millimeter accuracy including indoor multipath interference, system clock jitter and drift, local oscillator phase noise, sampling-rate limitations, and phase center error. This paper discusses sub-millimeter accuracy in UWB positioning for medical applications and outlines key challenges faced in achieving it with our UWB positioning system. Solutions to these challenges are also outlined followed by a discussion of future work needed to integrate the entire system.\",\"PeriodicalId\":430449,\"journal\":{\"name\":\"2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems\",\"volume\":\"92 32 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOWIRELESS.2011.5724360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2011.5724360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

超宽带(UWB)定位系统越来越多地用于室内环境,因为商业系统可以提供几厘米的三维精度。超宽带定位在医学上有许多应用,包括跟踪人员、资产和手术导航。我们设计了一个毫米精度的超宽带定位系统。某些应用,包括手术导航,在亚毫米范围内有更严格的精度要求。要实现亚毫米精度,必须克服许多挑战,包括室内多径干扰、系统时钟抖动和漂移、本振相位噪声、采样率限制和相位中心误差。本文讨论了医疗应用中超宽带定位的亚毫米精度,并概述了我们的超宽带定位系统实现亚毫米精度所面临的主要挑战。还概述了这些挑战的解决方案,然后讨论了整合整个系统所需的未来工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Towards sub-millimeter accuracy in UWB positioning for indoor medical environments
Ultra wideband (UWB) positioning systems are increasingly used in indoor environments since commercial systems can provide 3-D accuracy of a few centimeters. Many applications exist in medicine for UWB positioning which includes tracking personnel, assets, and surgical navigation. We have designed a UWB positioning system with millimeter accuracy. Certain applications, including surgical navigation, have even more stringent accuracy requirements in the sub-millimeter range. Many challenges must be overcome to achieve sub-millimeter accuracy including indoor multipath interference, system clock jitter and drift, local oscillator phase noise, sampling-rate limitations, and phase center error. This paper discusses sub-millimeter accuracy in UWB positioning for medical applications and outlines key challenges faced in achieving it with our UWB positioning system. Solutions to these challenges are also outlined followed by a discussion of future work needed to integrate the entire system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信