一种获取总功率接收机等效噪声温度的新方法

B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal
{"title":"一种获取总功率接收机等效噪声温度的新方法","authors":"B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal","doi":"10.1109/EUMA.2003.340963","DOIUrl":null,"url":null,"abstract":"A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.","PeriodicalId":156210,"journal":{"name":"2003 33rd European Microwave Conference, 2003","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A New Method to Obtain Total Power Receiver Equivalent Noise Temperature\",\"authors\":\"B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal\",\"doi\":\"10.1109/EUMA.2003.340963\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.\",\"PeriodicalId\":156210,\"journal\":{\"name\":\"2003 33rd European Microwave Conference, 2003\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 33rd European Microwave Conference, 2003\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMA.2003.340963\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 33rd European Microwave Conference, 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.2003.340963","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

提出了一种利用商用噪声源在室温下获得更精确的辐射计噪声温度的方法。在辐射计系统中使用的低噪声放大器具有等效噪声温度,它在其工作频率范围内将每个频率的等效噪声温度的贡献相加。y因子已得到改进和推广,以考虑噪声源的频率依赖性和接收器的传递函数。这种依赖性与宽带辐射计系统尤其相关。利用商业模拟器验证了该方法,并根据所提出的方法对ka波段总功率辐射计进行了表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A New Method to Obtain Total Power Receiver Equivalent Noise Temperature
A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信