B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal
{"title":"一种获取总功率接收机等效噪声温度的新方法","authors":"B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal","doi":"10.1109/EUMA.2003.340963","DOIUrl":null,"url":null,"abstract":"A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.","PeriodicalId":156210,"journal":{"name":"2003 33rd European Microwave Conference, 2003","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A New Method to Obtain Total Power Receiver Equivalent Noise Temperature\",\"authors\":\"B. Aja, J. P. Pascual, L. de la Fuente, J. Gallegos, E. Artal\",\"doi\":\"10.1109/EUMA.2003.340963\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.\",\"PeriodicalId\":156210,\"journal\":{\"name\":\"2003 33rd European Microwave Conference, 2003\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 33rd European Microwave Conference, 2003\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMA.2003.340963\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 33rd European Microwave Conference, 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.2003.340963","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A New Method to Obtain Total Power Receiver Equivalent Noise Temperature
A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.