{"title":"发展中国家的望远镜","authors":"G. Brooker","doi":"10.1109/ICST46873.2019.9047715","DOIUrl":null,"url":null,"abstract":"There are numerous examples in which the introduction of expensive medical equipment into the developing world fail for lack of understanding of the device, lack of spares or poor maintenance. This paper describes the development of a Fleisch pneumotachograph and cellphone based telespirometer that can easily be built from “junk box” medical and electronic components available in the developing world. This approach should introduce a sense of local ownership to the project as well as encouraging participation by the local electronics repair industry. Experimental results confirm that the forced expiratory flow data are reliably modulated onto an audio signal and transmitted by cellphone to a base station for examination by a district nurse or doctor. Flow measurement and data transmission accuracies are sufficiently good for remote diagnoses of chronic obstructive pulmonary disease.","PeriodicalId":344937,"journal":{"name":"2019 13th International Conference on Sensing Technology (ICST)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Telespirometer for the Developing World\",\"authors\":\"G. Brooker\",\"doi\":\"10.1109/ICST46873.2019.9047715\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are numerous examples in which the introduction of expensive medical equipment into the developing world fail for lack of understanding of the device, lack of spares or poor maintenance. This paper describes the development of a Fleisch pneumotachograph and cellphone based telespirometer that can easily be built from “junk box” medical and electronic components available in the developing world. This approach should introduce a sense of local ownership to the project as well as encouraging participation by the local electronics repair industry. Experimental results confirm that the forced expiratory flow data are reliably modulated onto an audio signal and transmitted by cellphone to a base station for examination by a district nurse or doctor. Flow measurement and data transmission accuracies are sufficiently good for remote diagnoses of chronic obstructive pulmonary disease.\",\"PeriodicalId\":344937,\"journal\":{\"name\":\"2019 13th International Conference on Sensing Technology (ICST)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 13th International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICST46873.2019.9047715\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 13th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICST46873.2019.9047715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于缺乏对设备的了解、缺乏备件或维护不善,向发展中国家引进昂贵医疗设备失败的例子不胜枚举。这篇论文描述了Fleisch气体记录仪和基于手机的望远镜的发展,这种望远镜可以很容易地从发展中国家的“垃圾箱”医疗和电子元件中制造出来。这种方法应该引入当地对项目的主人翁意识,并鼓励当地电子维修行业的参与。实验结果证实,用力呼气流量数据被可靠地调制成音频信号,并通过手机传输到基站,供地区护士或医生检查。流量测量和数据传输的准确性足以用于慢性阻塞性肺疾病的远程诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Telespirometer for the Developing World
There are numerous examples in which the introduction of expensive medical equipment into the developing world fail for lack of understanding of the device, lack of spares or poor maintenance. This paper describes the development of a Fleisch pneumotachograph and cellphone based telespirometer that can easily be built from “junk box” medical and electronic components available in the developing world. This approach should introduce a sense of local ownership to the project as well as encouraging participation by the local electronics repair industry. Experimental results confirm that the forced expiratory flow data are reliably modulated onto an audio signal and transmitted by cellphone to a base station for examination by a district nurse or doctor. Flow measurement and data transmission accuracies are sufficiently good for remote diagnoses of chronic obstructive pulmonary disease.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信