一种用于DG接入配电网故障诊断的微同步监控终端部署方法

Yang Wang, Wenbing Xi, Jian Chen, Ming Chen
{"title":"一种用于DG接入配电网故障诊断的微同步监控终端部署方法","authors":"Yang Wang, Wenbing Xi, Jian Chen, Ming Chen","doi":"10.1109/CPEEE51686.2021.9383399","DOIUrl":null,"url":null,"abstract":"With a large number of DG access to the distribution network, power quality problems and challenge of fault line selection are caused. It is important to monitor the node voltage and current of distribution network. In this paper, a deployment method of micro-synchronization monitoring terminal for distribution network fault diagnosis with DG access is proposed. According to whether there is relay protection device, the line is divided into protected line and unprotected line. Then, the rapid isolation deployment method is adopted for the protected lines. Meanwhile, according to the user demands, the unprotected lines are divided into precise decision line and fuzzy decision line. Finally, precise decision algorithm and fuzzy decision algorithm are used respectively for the precise decision lines and fuzzy decision lines. To verify the effectiveness of the method, a DG-containing distribution network was built in matlab, and the result shows that the method is effective.","PeriodicalId":314015,"journal":{"name":"2021 11th International Conference on Power, Energy and Electrical Engineering (CPEEE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Deployment Method of Micro-Synchronization Monitoring Terminal for Distribution Network Fault Diagnosis with DG Access\",\"authors\":\"Yang Wang, Wenbing Xi, Jian Chen, Ming Chen\",\"doi\":\"10.1109/CPEEE51686.2021.9383399\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With a large number of DG access to the distribution network, power quality problems and challenge of fault line selection are caused. It is important to monitor the node voltage and current of distribution network. In this paper, a deployment method of micro-synchronization monitoring terminal for distribution network fault diagnosis with DG access is proposed. According to whether there is relay protection device, the line is divided into protected line and unprotected line. Then, the rapid isolation deployment method is adopted for the protected lines. Meanwhile, according to the user demands, the unprotected lines are divided into precise decision line and fuzzy decision line. Finally, precise decision algorithm and fuzzy decision algorithm are used respectively for the precise decision lines and fuzzy decision lines. To verify the effectiveness of the method, a DG-containing distribution network was built in matlab, and the result shows that the method is effective.\",\"PeriodicalId\":314015,\"journal\":{\"name\":\"2021 11th International Conference on Power, Energy and Electrical Engineering (CPEEE)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 11th International Conference on Power, Energy and Electrical Engineering (CPEEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEEE51686.2021.9383399\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 11th International Conference on Power, Energy and Electrical Engineering (CPEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEEE51686.2021.9383399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

随着大量DG接入配电网,造成了电能质量问题和故障选线的挑战。对配电网节点电压、电流的监测具有重要意义。提出了一种用于DG接入配电网故障诊断的微同步监测终端部署方法。根据是否有继电保护装置,将线路分为受保护线路和不受保护线路。然后,对受保护线路采用快速隔离部署方法。同时,根据用户需求,将无保护线分为精确决策线和模糊决策线。最后,对精确决策线和模糊决策线分别采用精确决策算法和模糊决策算法。为了验证该方法的有效性,在matlab中建立了一个含dg的配电网,结果表明该方法是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Deployment Method of Micro-Synchronization Monitoring Terminal for Distribution Network Fault Diagnosis with DG Access
With a large number of DG access to the distribution network, power quality problems and challenge of fault line selection are caused. It is important to monitor the node voltage and current of distribution network. In this paper, a deployment method of micro-synchronization monitoring terminal for distribution network fault diagnosis with DG access is proposed. According to whether there is relay protection device, the line is divided into protected line and unprotected line. Then, the rapid isolation deployment method is adopted for the protected lines. Meanwhile, according to the user demands, the unprotected lines are divided into precise decision line and fuzzy decision line. Finally, precise decision algorithm and fuzzy decision algorithm are used respectively for the precise decision lines and fuzzy decision lines. To verify the effectiveness of the method, a DG-containing distribution network was built in matlab, and the result shows that the method is effective.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信