用于位置识别的电容瞬态判别

P. P. Pericolo, D. Niebur
{"title":"用于位置识别的电容瞬态判别","authors":"P. P. Pericolo, D. Niebur","doi":"10.1109/PESW.2001.916983","DOIUrl":null,"url":null,"abstract":"Capacitor banks are used extensively in power systems for power factor improvement or for compensation of reactive power demand of large commercial and industrial load. There are many occasions when capacitor bank switching on or off line is required, causing transients. These transients introduced by capacitor switching are becoming an increasing concern as modern equipment is more sensitive to power quality phenomena. This paper pursues the discrimination of positions of switching capacitors in order to take on-line and post-fault measures. This discrimination is done on radial distribution systems where two capacitor banks are present. The presented approach permits two different situations to be distinguished where one of the capacitor banks upstream or downstream of the load is switched and the other one is off. We discuss analytical and simulation results.","PeriodicalId":253534,"journal":{"name":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Discrimination of capacitor transients for position identification\",\"authors\":\"P. P. Pericolo, D. Niebur\",\"doi\":\"10.1109/PESW.2001.916983\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Capacitor banks are used extensively in power systems for power factor improvement or for compensation of reactive power demand of large commercial and industrial load. There are many occasions when capacitor bank switching on or off line is required, causing transients. These transients introduced by capacitor switching are becoming an increasing concern as modern equipment is more sensitive to power quality phenomena. This paper pursues the discrimination of positions of switching capacitors in order to take on-line and post-fault measures. This discrimination is done on radial distribution systems where two capacitor banks are present. The presented approach permits two different situations to be distinguished where one of the capacitor banks upstream or downstream of the load is switched and the other one is off. We discuss analytical and simulation results.\",\"PeriodicalId\":253534,\"journal\":{\"name\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESW.2001.916983\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2001.916983","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

电容器组广泛应用于电力系统中,用于改善功率因数或补偿大型商业和工业负荷的无功需求。在许多情况下,电容器组需要接通或断开,从而引起瞬变。随着现代设备对电能质量现象的日益敏感,由电容开关引入的暂态越来越受到人们的关注。本文研究了开关电容的位置判别,以便采取在线和故障后的措施。这种区分是在有两个电容器组的径向配电系统上进行的。所提出的方法允许区分两种不同的情况,其中一个电容器组的上游或下游负载被切换,另一个是关闭的。我们讨论了分析和仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Discrimination of capacitor transients for position identification
Capacitor banks are used extensively in power systems for power factor improvement or for compensation of reactive power demand of large commercial and industrial load. There are many occasions when capacitor bank switching on or off line is required, causing transients. These transients introduced by capacitor switching are becoming an increasing concern as modern equipment is more sensitive to power quality phenomena. This paper pursues the discrimination of positions of switching capacitors in order to take on-line and post-fault measures. This discrimination is done on radial distribution systems where two capacitor banks are present. The presented approach permits two different situations to be distinguished where one of the capacitor banks upstream or downstream of the load is switched and the other one is off. We discuss analytical and simulation results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信