{"title":"双极直流输电系统单相接地故障分析与仿真","authors":"Hua Li, Fuchang Lin, Junjia He, Yuxin Lu, Huisheng Ye, Zhigang Zhang","doi":"10.1109/PES.2007.385955","DOIUrl":null,"url":null,"abstract":"The paper analyses the monopolar grounding fault in bipolar HVDC system with phase-modal transformation method. Initial jumping voltage and maximum voltage on health pole with different kinds of termination are deduced by establishing the modal circuit under the fault. Simulation results show a grounding fault in the middle of the line exhibiting maximum voltage with value of 1.54 p.u, which agrees well with the theoretical value. And the maximum voltage decreases with the increasing grounding resistance. The inductance of the reactor influences the maximum voltage on health line a little.","PeriodicalId":380613,"journal":{"name":"2007 IEEE Power Engineering Society General Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Analysis and Simulation of Monopolar Grounding Fault in Bipolar HVDC Transmission System\",\"authors\":\"Hua Li, Fuchang Lin, Junjia He, Yuxin Lu, Huisheng Ye, Zhigang Zhang\",\"doi\":\"10.1109/PES.2007.385955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper analyses the monopolar grounding fault in bipolar HVDC system with phase-modal transformation method. Initial jumping voltage and maximum voltage on health pole with different kinds of termination are deduced by establishing the modal circuit under the fault. Simulation results show a grounding fault in the middle of the line exhibiting maximum voltage with value of 1.54 p.u, which agrees well with the theoretical value. And the maximum voltage decreases with the increasing grounding resistance. The inductance of the reactor influences the maximum voltage on health line a little.\",\"PeriodicalId\":380613,\"journal\":{\"name\":\"2007 IEEE Power Engineering Society General Meeting\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2007.385955\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2007.385955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis and Simulation of Monopolar Grounding Fault in Bipolar HVDC Transmission System
The paper analyses the monopolar grounding fault in bipolar HVDC system with phase-modal transformation method. Initial jumping voltage and maximum voltage on health pole with different kinds of termination are deduced by establishing the modal circuit under the fault. Simulation results show a grounding fault in the middle of the line exhibiting maximum voltage with value of 1.54 p.u, which agrees well with the theoretical value. And the maximum voltage decreases with the increasing grounding resistance. The inductance of the reactor influences the maximum voltage on health line a little.