现场,利用集成的毛细管流光学微流控装置平行检测水中生物分析物

Nuno M. M. Pires, T. Dong
{"title":"现场,利用集成的毛细管流光学微流控装置平行检测水中生物分析物","authors":"Nuno M. M. Pires, T. Dong","doi":"10.1109/MeMeA.2015.7145180","DOIUrl":null,"url":null,"abstract":"An integrated capillary-flow driven opto-microfluidic device for on-site, parallel detection of bio-analytes has been demonstrated in this work. An array of capillary-induced flow microchannels and chambers were arranged on a microfluidic chip made of poly(methyl methacrylate). This poly(methyl methacrylate) chip was further integrated with an array of eight ring-shaped organic photodiodes for measuring chemiluminescence of pathogen immunoassays. Highly sensitive detection of chemiluminescence was ensured by the use of gold nanoparticles, which were attached to the chambers of the microfluidic chip. The developed device demonstrated a detection limit in the range of ~104 cells/mL for bacteria detection in water. Furthermore, the device revealed feasibility to perform parallel detection of two types of bacteria and two types of viruses quantitatively. The presented concept may offer a promising route to realize truly in-the-field devices for medical and/or environmental measurements.","PeriodicalId":277757,"journal":{"name":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","volume":"7 9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On-site, parallel detection of bio-analytes in water by an integrated capillary flow based opto-microfluidic device\",\"authors\":\"Nuno M. M. Pires, T. Dong\",\"doi\":\"10.1109/MeMeA.2015.7145180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An integrated capillary-flow driven opto-microfluidic device for on-site, parallel detection of bio-analytes has been demonstrated in this work. An array of capillary-induced flow microchannels and chambers were arranged on a microfluidic chip made of poly(methyl methacrylate). This poly(methyl methacrylate) chip was further integrated with an array of eight ring-shaped organic photodiodes for measuring chemiluminescence of pathogen immunoassays. Highly sensitive detection of chemiluminescence was ensured by the use of gold nanoparticles, which were attached to the chambers of the microfluidic chip. The developed device demonstrated a detection limit in the range of ~104 cells/mL for bacteria detection in water. Furthermore, the device revealed feasibility to perform parallel detection of two types of bacteria and two types of viruses quantitatively. The presented concept may offer a promising route to realize truly in-the-field devices for medical and/or environmental measurements.\",\"PeriodicalId\":277757,\"journal\":{\"name\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"volume\":\"7 9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2015.7145180\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2015.7145180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一种集成的毛细管流驱动的光微流控装置,用于现场平行检测生物分析物。在聚甲基丙烯酸甲酯微流控芯片上设置了一系列毛细管诱导流动的微通道和微腔。该聚甲基丙烯酸甲酯芯片进一步集成了8个环形有机光电二极管阵列,用于测量病原体免疫分析的化学发光。利用金纳米颗粒附着在微流控芯片的腔室上,保证了化学发光的高灵敏度检测。该装置对水中细菌的检出限为~104个细胞/mL。此外,该装置还显示了对两种细菌和两种病毒进行定量平行检测的可行性。所提出的概念可能为实现用于医疗和/或环境测量的真正现场设备提供了一条有前途的途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On-site, parallel detection of bio-analytes in water by an integrated capillary flow based opto-microfluidic device
An integrated capillary-flow driven opto-microfluidic device for on-site, parallel detection of bio-analytes has been demonstrated in this work. An array of capillary-induced flow microchannels and chambers were arranged on a microfluidic chip made of poly(methyl methacrylate). This poly(methyl methacrylate) chip was further integrated with an array of eight ring-shaped organic photodiodes for measuring chemiluminescence of pathogen immunoassays. Highly sensitive detection of chemiluminescence was ensured by the use of gold nanoparticles, which were attached to the chambers of the microfluidic chip. The developed device demonstrated a detection limit in the range of ~104 cells/mL for bacteria detection in water. Furthermore, the device revealed feasibility to perform parallel detection of two types of bacteria and two types of viruses quantitatively. The presented concept may offer a promising route to realize truly in-the-field devices for medical and/or environmental measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信