M. Chowdhury, Md Rakib Hasan, M. Chowdhury, Saad Mohammad Bhuiya, Md. Saniat Rahman Zishan
{"title":"空调监控管理系统的设计与开发","authors":"M. Chowdhury, Md Rakib Hasan, M. Chowdhury, Saad Mohammad Bhuiya, Md. Saniat Rahman Zishan","doi":"10.53799/ajse.v21i3.260","DOIUrl":null,"url":null,"abstract":"Nowadays Air Conditioner (AC) has become a more important appliance in our life. Gas leakage, blockage in the evaporator and compressor coil, pipelines as well as dust in the air filters, are the major reasons behind AC explosion. Many people have been injured over the years due to AC blasts. In this paper a system is developed that uses sensor technology and smart devices to reduce AC blast. As a result, pipeline leaks or blockage fault detection system is planned and constructed using MQ-02, TTC 103, optical dust sensors for gas detection, temperature detection and for detecting dust density respectively. Also bacteria can be detected through MQ-3 gas sensor as it combines with AC refrigerant and produces ethanol. This system is also digitally connected to smart devices (cellphones) and a control device (RM MINI 3) so that user can receive a detection notification at any time and operate AC from any location. By implementing these sensors, the initial target was achieved. The work is low cost and environment friendly. \n \nIndex Terms— Explosions, blockage, leakage, RM MINI 3, cellphone, refrigeration cycle, sensor, safety \n ","PeriodicalId":224436,"journal":{"name":"AIUB Journal of Science and Engineering (AJSE)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design And Development Of Air Conditioner (AC) Monitoring And Management System\",\"authors\":\"M. Chowdhury, Md Rakib Hasan, M. Chowdhury, Saad Mohammad Bhuiya, Md. Saniat Rahman Zishan\",\"doi\":\"10.53799/ajse.v21i3.260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays Air Conditioner (AC) has become a more important appliance in our life. Gas leakage, blockage in the evaporator and compressor coil, pipelines as well as dust in the air filters, are the major reasons behind AC explosion. Many people have been injured over the years due to AC blasts. In this paper a system is developed that uses sensor technology and smart devices to reduce AC blast. As a result, pipeline leaks or blockage fault detection system is planned and constructed using MQ-02, TTC 103, optical dust sensors for gas detection, temperature detection and for detecting dust density respectively. Also bacteria can be detected through MQ-3 gas sensor as it combines with AC refrigerant and produces ethanol. This system is also digitally connected to smart devices (cellphones) and a control device (RM MINI 3) so that user can receive a detection notification at any time and operate AC from any location. By implementing these sensors, the initial target was achieved. The work is low cost and environment friendly. \\n \\nIndex Terms— Explosions, blockage, leakage, RM MINI 3, cellphone, refrigeration cycle, sensor, safety \\n \",\"PeriodicalId\":224436,\"journal\":{\"name\":\"AIUB Journal of Science and Engineering (AJSE)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIUB Journal of Science and Engineering (AJSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53799/ajse.v21i3.260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIUB Journal of Science and Engineering (AJSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53799/ajse.v21i3.260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
如今,空调(AC)已成为我们生活中越来越重要的电器。气体泄漏,蒸发器和压缩机盘管堵塞,管道堵塞以及空气过滤器中的灰尘是交流爆炸的主要原因。多年来,由于交流电爆炸,许多人受伤。本文开发了一种利用传感器技术和智能设备来降低交流爆炸的系统。为此,规划构建了管道泄漏或堵塞故障检测系统,采用MQ-02、TTC 103、光学粉尘传感器分别进行气体检测、温度检测和粉尘密度检测。另外,通过MQ-3型气体传感器可以检测到细菌,因为它与交流制冷剂结合产生乙醇。该系统还与智能设备(手机)和控制设备(RM MINI 3)进行数字连接,以便用户可以随时收到检测通知,并从任何位置操作AC。通过实施这些传感器,实现了最初的目标。这项工作成本低,对环境友好。索引术语-爆炸,堵塞,泄漏,RM MINI 3,手机,制冷循环,传感器,安全
Design And Development Of Air Conditioner (AC) Monitoring And Management System
Nowadays Air Conditioner (AC) has become a more important appliance in our life. Gas leakage, blockage in the evaporator and compressor coil, pipelines as well as dust in the air filters, are the major reasons behind AC explosion. Many people have been injured over the years due to AC blasts. In this paper a system is developed that uses sensor technology and smart devices to reduce AC blast. As a result, pipeline leaks or blockage fault detection system is planned and constructed using MQ-02, TTC 103, optical dust sensors for gas detection, temperature detection and for detecting dust density respectively. Also bacteria can be detected through MQ-3 gas sensor as it combines with AC refrigerant and produces ethanol. This system is also digitally connected to smart devices (cellphones) and a control device (RM MINI 3) so that user can receive a detection notification at any time and operate AC from any location. By implementing these sensors, the initial target was achieved. The work is low cost and environment friendly.
Index Terms— Explosions, blockage, leakage, RM MINI 3, cellphone, refrigeration cycle, sensor, safety