NIST支持相量测量,以提高北美电网的可靠性

G. Stenbakken, T. Nelson
{"title":"NIST支持相量测量,以提高北美电网的可靠性","authors":"G. Stenbakken, T. Nelson","doi":"10.1109/PES.2006.1709191","DOIUrl":null,"url":null,"abstract":"The importance of developing better tools for observing the status of the North American power grid is described. Focus is on the performance of the phase measurement units being deployed to give the raw data for this improved observability. How the availability of this information would have appeared during the August 2003 power blackout is described. IEEE is developing a standard for these units but no calibration service is available to use as a common reference to assure the interchangeability of units from different manufacturers. The program under way at NIST to develop such a calibration service and the coordination with the power industry to develop a guideline for performing these calibrations is presented. The future directions of work in this area are given","PeriodicalId":267582,"journal":{"name":"2006 IEEE Power Engineering Society General Meeting","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"NIST support of phasor measurements to increase reliability of the North American electric power grid\",\"authors\":\"G. Stenbakken, T. Nelson\",\"doi\":\"10.1109/PES.2006.1709191\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The importance of developing better tools for observing the status of the North American power grid is described. Focus is on the performance of the phase measurement units being deployed to give the raw data for this improved observability. How the availability of this information would have appeared during the August 2003 power blackout is described. IEEE is developing a standard for these units but no calibration service is available to use as a common reference to assure the interchangeability of units from different manufacturers. The program under way at NIST to develop such a calibration service and the coordination with the power industry to develop a guideline for performing these calibrations is presented. The future directions of work in this area are given\",\"PeriodicalId\":267582,\"journal\":{\"name\":\"2006 IEEE Power Engineering Society General Meeting\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2006.1709191\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2006.1709191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

介绍了开发更好的工具来观察北美电网状况的重要性。重点是部署的相位测量单元的性能,为改进的可观测性提供原始数据。描述了在2003年8月停电期间这些信息的可用性是如何出现的。IEEE正在为这些单位制定标准,但没有可用的校准服务作为通用参考,以确保来自不同制造商的单位的互换性。NIST正在进行的开发这种校准服务的计划,以及与电力行业的协调,以制定执行这些校准的指南。最后提出了该领域今后的工作方向
本文章由计算机程序翻译,如有差异,请以英文原文为准。
NIST support of phasor measurements to increase reliability of the North American electric power grid
The importance of developing better tools for observing the status of the North American power grid is described. Focus is on the performance of the phase measurement units being deployed to give the raw data for this improved observability. How the availability of this information would have appeared during the August 2003 power blackout is described. IEEE is developing a standard for these units but no calibration service is available to use as a common reference to assure the interchangeability of units from different manufacturers. The program under way at NIST to develop such a calibration service and the coordination with the power industry to develop a guideline for performing these calibrations is presented. The future directions of work in this area are given
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信