M. Drif, P. Pérez-Higueras, J. Aguilera, A. Mellit
{"title":"一种利用实际数据评估GC-BIPV中遮阳损失的方法","authors":"M. Drif, P. Pérez-Higueras, J. Aguilera, A. Mellit","doi":"10.1109/SSD.2012.6198070","DOIUrl":null,"url":null,"abstract":"This paper presents a simplified method for evaluating the energy loss involved in a grid connected building integrated photovoltaic (GC-BIPV) system due to partial shading. The method consists in the comparison of the monthly theoretical curve (for un-shaded PV generator) and real fitted curve (deducted from monitoring data) of the maximum energy produced by the PV generator.","PeriodicalId":425823,"journal":{"name":"International Multi-Conference on Systems, Sygnals & Devices","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A method for evaluating shading losses involved in a GC-BIPV using real data\",\"authors\":\"M. Drif, P. Pérez-Higueras, J. Aguilera, A. Mellit\",\"doi\":\"10.1109/SSD.2012.6198070\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a simplified method for evaluating the energy loss involved in a grid connected building integrated photovoltaic (GC-BIPV) system due to partial shading. The method consists in the comparison of the monthly theoretical curve (for un-shaded PV generator) and real fitted curve (deducted from monitoring data) of the maximum energy produced by the PV generator.\",\"PeriodicalId\":425823,\"journal\":{\"name\":\"International Multi-Conference on Systems, Sygnals & Devices\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Multi-Conference on Systems, Sygnals & Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSD.2012.6198070\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Multi-Conference on Systems, Sygnals & Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSD.2012.6198070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A method for evaluating shading losses involved in a GC-BIPV using real data
This paper presents a simplified method for evaluating the energy loss involved in a grid connected building integrated photovoltaic (GC-BIPV) system due to partial shading. The method consists in the comparison of the monthly theoretical curve (for un-shaded PV generator) and real fitted curve (deducted from monitoring data) of the maximum energy produced by the PV generator.