混凝土楼板的永久性FRP模板

X. Gai, A. Darby, T. Ibell, M. Evernden
{"title":"混凝土楼板的永久性FRP模板","authors":"X. Gai, A. Darby, T. Ibell, M. Evernden","doi":"10.14359/51682465","DOIUrl":null,"url":null,"abstract":"This paper presents a new concept for an FRP-Concrete composite floor system. The system consists of a moulded glass fibre reinforced polymer (GFRP) grating adhesively bonded to rectangular pultruded GFRP box sections as structural formwork for a concrete slab. Holes cut into the top flange of the box sections at a variable spacing allow concrete ’studs’ to form at the grating/box interface. During casting, GFRP dowels are inserted into the holes to further connect the grating and box sections. Following preliminary component tests on two concrete blocks, experimental results show that the concrete filled grating provides a 100% increase in strain capacity when compared to a plain concrete block. It is therefore feasible to provide ductility to the complete system through the concrete in compression. Four push-out GFRP grating-box section specimens were then tested in double shear to assess the shear behaviour of the proposed GFRP dowel shear connector in both partially concrete-filled and fully concrete-filled box sections. From the resulting load-slip curves, a progressive longitudinal shear failure was seen to be provided by such a connection. The experimental results indicate that this type of shear connection can provide robustness and reasonable ductility to the system. Research is now underway to test a complete prototype system under variable load conditions to examine whether the behaviour is as predicted","PeriodicalId":375782,"journal":{"name":"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Permanent Participating FRP Formwork for Concrete Floor Slabs\",\"authors\":\"X. Gai, A. Darby, T. Ibell, M. Evernden\",\"doi\":\"10.14359/51682465\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new concept for an FRP-Concrete composite floor system. The system consists of a moulded glass fibre reinforced polymer (GFRP) grating adhesively bonded to rectangular pultruded GFRP box sections as structural formwork for a concrete slab. Holes cut into the top flange of the box sections at a variable spacing allow concrete ’studs’ to form at the grating/box interface. During casting, GFRP dowels are inserted into the holes to further connect the grating and box sections. Following preliminary component tests on two concrete blocks, experimental results show that the concrete filled grating provides a 100% increase in strain capacity when compared to a plain concrete block. It is therefore feasible to provide ductility to the complete system through the concrete in compression. Four push-out GFRP grating-box section specimens were then tested in double shear to assess the shear behaviour of the proposed GFRP dowel shear connector in both partially concrete-filled and fully concrete-filled box sections. From the resulting load-slip curves, a progressive longitudinal shear failure was seen to be provided by such a connection. The experimental results indicate that this type of shear connection can provide robustness and reasonable ductility to the system. Research is now underway to test a complete prototype system under variable load conditions to examine whether the behaviour is as predicted\",\"PeriodicalId\":375782,\"journal\":{\"name\":\"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/51682465\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/51682465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了frp -混凝土复合楼盖体系的新概念。该系统由模压玻璃纤维增强聚合物(GFRP)光栅组成,该光栅与矩形拉伸GFRP盒段粘合在一起,作为混凝土板的结构模板。在箱体部分的顶部法兰上以可变间距切割孔,使混凝土“螺柱”在光栅/箱体界面形成。浇注时,在孔内插入玻璃钢销钉,进一步连接格栅和箱段。通过对两块混凝土砌块进行初步构件试验,试验结果表明,与普通混凝土砌块相比,混凝土填充格栅的应变能力提高了100%。因此,通过受压混凝土为整个体系提供延性是可行的。然后在双剪中测试了四个推出的GFRP格栅盒截面试件,以评估建议的GFRP榫剪接头在部分混凝土填充和完全混凝土填充盒截面中的剪切性能。从由此产生的荷载-滑移曲线来看,这种连接提供了一个渐进的纵向剪切破坏。试验结果表明,这种剪切连接方式能够保证系统的鲁棒性和合理的延性。目前正在进行的研究是在可变负载条件下测试一个完整的原型系统,以检查其行为是否如预测的那样
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Permanent Participating FRP Formwork for Concrete Floor Slabs
This paper presents a new concept for an FRP-Concrete composite floor system. The system consists of a moulded glass fibre reinforced polymer (GFRP) grating adhesively bonded to rectangular pultruded GFRP box sections as structural formwork for a concrete slab. Holes cut into the top flange of the box sections at a variable spacing allow concrete ’studs’ to form at the grating/box interface. During casting, GFRP dowels are inserted into the holes to further connect the grating and box sections. Following preliminary component tests on two concrete blocks, experimental results show that the concrete filled grating provides a 100% increase in strain capacity when compared to a plain concrete block. It is therefore feasible to provide ductility to the complete system through the concrete in compression. Four push-out GFRP grating-box section specimens were then tested in double shear to assess the shear behaviour of the proposed GFRP dowel shear connector in both partially concrete-filled and fully concrete-filled box sections. From the resulting load-slip curves, a progressive longitudinal shear failure was seen to be provided by such a connection. The experimental results indicate that this type of shear connection can provide robustness and reasonable ductility to the system. Research is now underway to test a complete prototype system under variable load conditions to examine whether the behaviour is as predicted
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信