{"title":"原子序数26 = Z = 70范围内某些元素的k壳x射线荧光研究","authors":"Punchithaya K. Sripathi, K. M. Balakrishna","doi":"10.4018/ijcce.2013070102","DOIUrl":null,"url":null,"abstract":"K-shell fluorescence yields of low, medium Z and rare earth elements were determined using SiPIN detector and HPGe detector employing reflection geometry set up. Target atoms were excited using 59.5 keV gamma rays emerging from Am-241 source of strength 300 mCi. Background radiation and multiple scattering effects were minimized by properly shielding the detector. The elemental foils of uniform thickness and 99.9% purity were used in the present investigation. The fluorescent spectra were recorded in an 8K and 16K multi channel analyzer. The data were carefully analyzed and total K-shell fluorescence yields were calculated. The resulting yield values are compared with the available experimental and theoretical values.","PeriodicalId":132974,"journal":{"name":"Int. J. Chemoinformatics Chem. Eng.","volume":"58 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"K-Shell X-Ray Fluorescence Studies of Some Elements in the Atomic Number Range 26 = Z = 70\",\"authors\":\"Punchithaya K. Sripathi, K. M. Balakrishna\",\"doi\":\"10.4018/ijcce.2013070102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"K-shell fluorescence yields of low, medium Z and rare earth elements were determined using SiPIN detector and HPGe detector employing reflection geometry set up. Target atoms were excited using 59.5 keV gamma rays emerging from Am-241 source of strength 300 mCi. Background radiation and multiple scattering effects were minimized by properly shielding the detector. The elemental foils of uniform thickness and 99.9% purity were used in the present investigation. The fluorescent spectra were recorded in an 8K and 16K multi channel analyzer. The data were carefully analyzed and total K-shell fluorescence yields were calculated. The resulting yield values are compared with the available experimental and theoretical values.\",\"PeriodicalId\":132974,\"journal\":{\"name\":\"Int. J. Chemoinformatics Chem. Eng.\",\"volume\":\"58 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Int. J. Chemoinformatics Chem. Eng.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/ijcce.2013070102\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Int. J. Chemoinformatics Chem. Eng.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/ijcce.2013070102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
K-Shell X-Ray Fluorescence Studies of Some Elements in the Atomic Number Range 26 = Z = 70
K-shell fluorescence yields of low, medium Z and rare earth elements were determined using SiPIN detector and HPGe detector employing reflection geometry set up. Target atoms were excited using 59.5 keV gamma rays emerging from Am-241 source of strength 300 mCi. Background radiation and multiple scattering effects were minimized by properly shielding the detector. The elemental foils of uniform thickness and 99.9% purity were used in the present investigation. The fluorescent spectra were recorded in an 8K and 16K multi channel analyzer. The data were carefully analyzed and total K-shell fluorescence yields were calculated. The resulting yield values are compared with the available experimental and theoretical values.