一种基于测量信息修正的单元超前相位能力评估方法

Bin Chen, Quan Yuan, Yi Tang, Jianye Huang, Gonglin Zhang, Yuanliang Fan
{"title":"一种基于测量信息修正的单元超前相位能力评估方法","authors":"Bin Chen, Quan Yuan, Yi Tang, Jianye Huang, Gonglin Zhang, Yuanliang Fan","doi":"10.1109/ICIEA.2018.8397822","DOIUrl":null,"url":null,"abstract":"Leading phase operation of generator has important significance on voltage regulation of power system. In order to reduce the large error of auxiliary power load model and diversify the test condition, this paper proposes a simulation method of thermal power unit leading phase ability based on auxiliary power load correction model. Firstly, an auxiliary power load correction model is put forward with parameter identification method base on operational data of power plant. Secondly, this paper tests thermal power unit leading phase ability on different system voltages and unit output. The case study tests thermal power unit leading phase ability based on operational data of an actual generating unit between June 2013 and June 2016, and compares simulation results with leading phase test result. The proposed method is confirmed to be effective and reasonable.","PeriodicalId":140420,"journal":{"name":"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A method to assess the leading phase ability of units based on the measured information correction\",\"authors\":\"Bin Chen, Quan Yuan, Yi Tang, Jianye Huang, Gonglin Zhang, Yuanliang Fan\",\"doi\":\"10.1109/ICIEA.2018.8397822\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Leading phase operation of generator has important significance on voltage regulation of power system. In order to reduce the large error of auxiliary power load model and diversify the test condition, this paper proposes a simulation method of thermal power unit leading phase ability based on auxiliary power load correction model. Firstly, an auxiliary power load correction model is put forward with parameter identification method base on operational data of power plant. Secondly, this paper tests thermal power unit leading phase ability on different system voltages and unit output. The case study tests thermal power unit leading phase ability based on operational data of an actual generating unit between June 2013 and June 2016, and compares simulation results with leading phase test result. The proposed method is confirmed to be effective and reasonable.\",\"PeriodicalId\":140420,\"journal\":{\"name\":\"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2018.8397822\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 13th IEEE Conference on Industrial Electronics and Applications (ICIEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2018.8397822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

发电机的进相运行对电力系统的电压调节具有重要意义。为了减小辅助负荷模型的较大误差,使试验条件多样化,本文提出了一种基于辅助负荷修正模型的火电机组超前相能力仿真方法。首先,基于电厂运行数据,采用参数辨识方法建立了电厂辅助负荷修正模型;其次,对不同系统电压和机组输出下的火电机组超前相能力进行了测试。本案例以2013年6月至2016年6月某实际发电机组运行数据为基础,对火电机组导相能力进行了测试,并将模拟结果与导相试验结果进行了对比。验证了该方法的有效性和合理性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A method to assess the leading phase ability of units based on the measured information correction
Leading phase operation of generator has important significance on voltage regulation of power system. In order to reduce the large error of auxiliary power load model and diversify the test condition, this paper proposes a simulation method of thermal power unit leading phase ability based on auxiliary power load correction model. Firstly, an auxiliary power load correction model is put forward with parameter identification method base on operational data of power plant. Secondly, this paper tests thermal power unit leading phase ability on different system voltages and unit output. The case study tests thermal power unit leading phase ability based on operational data of an actual generating unit between June 2013 and June 2016, and compares simulation results with leading phase test result. The proposed method is confirmed to be effective and reasonable.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信