{"title":"风电并网逆变器谐波补偿改进QPR功率控制器","authors":"Sun Jian, Eid A. Amin, Zhang Yunning","doi":"10.7176/cti/8-05","DOIUrl":null,"url":null,"abstract":"The grid-connected inverter plays an important role in wind turbine grid-connected power generation system. The performance of inverter control strategy directly affects the grid-connected current quality. For quasi-proportional resonant(QPR) control, the output signal step of controller exists owing to the input signal step, and the grid current will be distorted by the low-frequency noise in the input signal. In order to solve these problems, the performance of quasi-PR control should be improved, so a method of constructing quasi-PR controller with two degrees of freedom is adopted, by which the improved controller can effectively suppress the influence of the step and low-frequency noise in the input signal on the grid-connected current. The improved controller is simulated on MATLAB, and the results show that the applied method can effectively improve the property of the existing problems of quasi-QPR controller and the quality of grid-connected current. Keywords: Grid-connected inverter, Harmonic compensator, Matlab/Simulation, 2-DOF,QPR. DOI: 10.7176/CTI/8-05","PeriodicalId":437485,"journal":{"name":"Control Theory and Informatics","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved QPR Power Controller With Harmonic Compensator For Wind Grid-Connected Inverter\",\"authors\":\"Sun Jian, Eid A. Amin, Zhang Yunning\",\"doi\":\"10.7176/cti/8-05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The grid-connected inverter plays an important role in wind turbine grid-connected power generation system. The performance of inverter control strategy directly affects the grid-connected current quality. For quasi-proportional resonant(QPR) control, the output signal step of controller exists owing to the input signal step, and the grid current will be distorted by the low-frequency noise in the input signal. In order to solve these problems, the performance of quasi-PR control should be improved, so a method of constructing quasi-PR controller with two degrees of freedom is adopted, by which the improved controller can effectively suppress the influence of the step and low-frequency noise in the input signal on the grid-connected current. The improved controller is simulated on MATLAB, and the results show that the applied method can effectively improve the property of the existing problems of quasi-QPR controller and the quality of grid-connected current. Keywords: Grid-connected inverter, Harmonic compensator, Matlab/Simulation, 2-DOF,QPR. DOI: 10.7176/CTI/8-05\",\"PeriodicalId\":437485,\"journal\":{\"name\":\"Control Theory and Informatics\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Control Theory and Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7176/cti/8-05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Control Theory and Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7176/cti/8-05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improved QPR Power Controller With Harmonic Compensator For Wind Grid-Connected Inverter
The grid-connected inverter plays an important role in wind turbine grid-connected power generation system. The performance of inverter control strategy directly affects the grid-connected current quality. For quasi-proportional resonant(QPR) control, the output signal step of controller exists owing to the input signal step, and the grid current will be distorted by the low-frequency noise in the input signal. In order to solve these problems, the performance of quasi-PR control should be improved, so a method of constructing quasi-PR controller with two degrees of freedom is adopted, by which the improved controller can effectively suppress the influence of the step and low-frequency noise in the input signal on the grid-connected current. The improved controller is simulated on MATLAB, and the results show that the applied method can effectively improve the property of the existing problems of quasi-QPR controller and the quality of grid-connected current. Keywords: Grid-connected inverter, Harmonic compensator, Matlab/Simulation, 2-DOF,QPR. DOI: 10.7176/CTI/8-05