用于灵敏质量检测的网状悬挑耦合微悬臂梁

G. Cai, R. Zhang, Zhiqiang Wang, Lurui Zhao, Wengang Wu
{"title":"用于灵敏质量检测的网状悬挑耦合微悬臂梁","authors":"G. Cai, R. Zhang, Zhiqiang Wang, Lurui Zhao, Wengang Wu","doi":"10.1109/ICSENS.2013.6688214","DOIUrl":null,"url":null,"abstract":"This paper presents a kind of net-overhang coupled microcantilevers for ultrasensitive mass detection. Because of the coupling through the net overhang, each cantilever would resonate in two different modes (in-phase and out-of-phase modes). Mass sensitivity of the structure based on relative changes of amplitude ratio between the two cantilevers' in-phase modes is nearly two orders greater than that based on traditionally used resonant frequency shifts. Furthermore, compared with ambient tests, results under vacuum condition demonstrate improved sensitivity and easier emergence of out-of-phase states. Besides, the amplitude ratios show better stability in comparison with the resonant amplitudes and this would contribute to a better detection resolution.","PeriodicalId":258260,"journal":{"name":"2013 IEEE SENSORS","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Net-overhang coupled microcantilevers for sensitive mass detection\",\"authors\":\"G. Cai, R. Zhang, Zhiqiang Wang, Lurui Zhao, Wengang Wu\",\"doi\":\"10.1109/ICSENS.2013.6688214\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a kind of net-overhang coupled microcantilevers for ultrasensitive mass detection. Because of the coupling through the net overhang, each cantilever would resonate in two different modes (in-phase and out-of-phase modes). Mass sensitivity of the structure based on relative changes of amplitude ratio between the two cantilevers' in-phase modes is nearly two orders greater than that based on traditionally used resonant frequency shifts. Furthermore, compared with ambient tests, results under vacuum condition demonstrate improved sensitivity and easier emergence of out-of-phase states. Besides, the amplitude ratios show better stability in comparison with the resonant amplitudes and this would contribute to a better detection resolution.\",\"PeriodicalId\":258260,\"journal\":{\"name\":\"2013 IEEE SENSORS\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2013.6688214\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2013.6688214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种用于超灵敏质量检测的净悬挑耦合微悬臂梁。由于通过网悬挑的耦合,每个悬臂将以两种不同的模式(同相模式和非同相模式)谐振。基于两悬臂梁同相模态幅值比相对变化的结构质量灵敏度比基于传统谐振频移的结构质量灵敏度高近两个数量级。此外,与环境试验相比,真空条件下的结果灵敏度更高,更容易出现失相状态。此外,振幅比与共振振幅相比具有更好的稳定性,这将有助于提高检测分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Net-overhang coupled microcantilevers for sensitive mass detection
This paper presents a kind of net-overhang coupled microcantilevers for ultrasensitive mass detection. Because of the coupling through the net overhang, each cantilever would resonate in two different modes (in-phase and out-of-phase modes). Mass sensitivity of the structure based on relative changes of amplitude ratio between the two cantilevers' in-phase modes is nearly two orders greater than that based on traditionally used resonant frequency shifts. Furthermore, compared with ambient tests, results under vacuum condition demonstrate improved sensitivity and easier emergence of out-of-phase states. Besides, the amplitude ratios show better stability in comparison with the resonant amplitudes and this would contribute to a better detection resolution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信