微加工晶圆探头

T. Reck, Lihan Chen, Chunhu Zhang, C. Groppi, Haiyong Xu, A. Arsenovic, N. S. Barker, A. Lichtenberger, R. Weikle
{"title":"微加工晶圆探头","authors":"T. Reck, Lihan Chen, Chunhu Zhang, C. Groppi, Haiyong Xu, A. Arsenovic, N. S. Barker, A. Lichtenberger, R. Weikle","doi":"10.1109/MWSYM.2010.5517580","DOIUrl":null,"url":null,"abstract":"A micromachined on-wafer probe is designed, fabricated and measured at W-Band as a proof of concept for probes operating at sub-millimeter wavelengths. A fabrication process is developed to create devices that combine a waveguide probe with a GSG probe tip on a 15 µm silicon substrate. This device is housed in a metal machined waveguide block that provides mechanical support for the probe and connection to a waveguide flange. Load-cell measurements show a DC contact resistance below 0.07 Ω with a force of 1 mN. A two-tier TRL calibration characterizes the operation of the electromagnetic design and an insertion loss of 1.75 dB is achieved; this is comparable with commercial probes operating in the same band.","PeriodicalId":341557,"journal":{"name":"2010 IEEE MTT-S International Microwave Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Micromachined on-wafer probes\",\"authors\":\"T. Reck, Lihan Chen, Chunhu Zhang, C. Groppi, Haiyong Xu, A. Arsenovic, N. S. Barker, A. Lichtenberger, R. Weikle\",\"doi\":\"10.1109/MWSYM.2010.5517580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A micromachined on-wafer probe is designed, fabricated and measured at W-Band as a proof of concept for probes operating at sub-millimeter wavelengths. A fabrication process is developed to create devices that combine a waveguide probe with a GSG probe tip on a 15 µm silicon substrate. This device is housed in a metal machined waveguide block that provides mechanical support for the probe and connection to a waveguide flange. Load-cell measurements show a DC contact resistance below 0.07 Ω with a force of 1 mN. A two-tier TRL calibration characterizes the operation of the electromagnetic design and an insertion loss of 1.75 dB is achieved; this is comparable with commercial probes operating in the same band.\",\"PeriodicalId\":341557,\"journal\":{\"name\":\"2010 IEEE MTT-S International Microwave Symposium\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE MTT-S International Microwave Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2010.5517580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE MTT-S International Microwave Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2010.5517580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

摘要

在w波段设计、制造和测量了微机械晶圆上探头,作为亚毫米波长探头工作的概念证明。开发了一种制造工艺,用于创建将波导探针与GSG探针尖端结合在15 μ m硅衬底上的器件。该装置安装在金属加工波导块中,为探头提供机械支撑,并连接到波导法兰。测压元件测量结果显示,直流接触电阻低于0.07 Ω,力为1mn。两层TRL校准表征了电磁设计的运行,并实现了1.75 dB的插入损耗;这与在同一频段工作的商用探测器相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Micromachined on-wafer probes
A micromachined on-wafer probe is designed, fabricated and measured at W-Band as a proof of concept for probes operating at sub-millimeter wavelengths. A fabrication process is developed to create devices that combine a waveguide probe with a GSG probe tip on a 15 µm silicon substrate. This device is housed in a metal machined waveguide block that provides mechanical support for the probe and connection to a waveguide flange. Load-cell measurements show a DC contact resistance below 0.07 Ω with a force of 1 mN. A two-tier TRL calibration characterizes the operation of the electromagnetic design and an insertion loss of 1.75 dB is achieved; this is comparable with commercial probes operating in the same band.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信