B. Diaz, T. Ortmeyer, B. Pilvelait, M. Izenson, Weibo Chen, N. Spivey
{"title":"船用电力系统故障限流器的系统研究","authors":"B. Diaz, T. Ortmeyer, B. Pilvelait, M. Izenson, Weibo Chen, N. Spivey","doi":"10.1109/ESTS.2009.4906539","DOIUrl":null,"url":null,"abstract":"Fault current limiters are an attractive option for high fault current duty shipboard power systems. FCL's have the potential to improve safety and reliability, and limit the size and rating of protective equipment, and limit the extent of voltage sags and interruptions. This paper explores the system performance of a novel superconducting fault current limiter.","PeriodicalId":446953,"journal":{"name":"2009 IEEE Electric Ship Technologies Symposium","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"System study of fault current limiter for shipboard power system\",\"authors\":\"B. Diaz, T. Ortmeyer, B. Pilvelait, M. Izenson, Weibo Chen, N. Spivey\",\"doi\":\"10.1109/ESTS.2009.4906539\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fault current limiters are an attractive option for high fault current duty shipboard power systems. FCL's have the potential to improve safety and reliability, and limit the size and rating of protective equipment, and limit the extent of voltage sags and interruptions. This paper explores the system performance of a novel superconducting fault current limiter.\",\"PeriodicalId\":446953,\"journal\":{\"name\":\"2009 IEEE Electric Ship Technologies Symposium\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Electric Ship Technologies Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTS.2009.4906539\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Electric Ship Technologies Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2009.4906539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
System study of fault current limiter for shipboard power system
Fault current limiters are an attractive option for high fault current duty shipboard power systems. FCL's have the potential to improve safety and reliability, and limit the size and rating of protective equipment, and limit the extent of voltage sags and interruptions. This paper explores the system performance of a novel superconducting fault current limiter.