二电平逆变器供电三相异步电动机过电压的研究

Henda Bouyahi, K. Smida, A. Khedher
{"title":"二电平逆变器供电三相异步电动机过电压的研究","authors":"Henda Bouyahi, K. Smida, A. Khedher","doi":"10.1109/SCC47175.2019.9116098","DOIUrl":null,"url":null,"abstract":"The use of long cables in the PWM inverter-motor association generate transient voltage pulses at the inverter which consequently behaves like progressive waves on these cables. Thereby, this phenomenon produces voltage reflection that causes overvoltage problem at the motor terminals. High frequency simulation models for the cables and motors are the key tools to obtain an accurate study of overvoltage problem. In this paper, the high frequency models of cable and induction motor are developed and implemented in Simulink. The simulation results show that the overvoltage at the motor terminals increases when the length of cable and switching frequency increase.","PeriodicalId":133593,"journal":{"name":"2019 International Conference on Signal, Control and Communication (SCC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the overvoltage of three phase induction motor fed by two levels inverter\",\"authors\":\"Henda Bouyahi, K. Smida, A. Khedher\",\"doi\":\"10.1109/SCC47175.2019.9116098\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of long cables in the PWM inverter-motor association generate transient voltage pulses at the inverter which consequently behaves like progressive waves on these cables. Thereby, this phenomenon produces voltage reflection that causes overvoltage problem at the motor terminals. High frequency simulation models for the cables and motors are the key tools to obtain an accurate study of overvoltage problem. In this paper, the high frequency models of cable and induction motor are developed and implemented in Simulink. The simulation results show that the overvoltage at the motor terminals increases when the length of cable and switching frequency increase.\",\"PeriodicalId\":133593,\"journal\":{\"name\":\"2019 International Conference on Signal, Control and Communication (SCC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Signal, Control and Communication (SCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCC47175.2019.9116098\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Signal, Control and Communication (SCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCC47175.2019.9116098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在PWM逆变器-电机关联中使用长电缆在逆变器处产生瞬态电压脉冲,因此在这些电缆上表现得像渐进波。因此,这种现象产生电压反射,导致电机端子过电压问题。电缆和电机的高频仿真模型是准确研究过电压问题的关键工具。本文在Simulink中开发并实现了电缆和感应电机的高频模型。仿真结果表明,随着电缆长度和开关频率的增加,电机端过电压增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On the overvoltage of three phase induction motor fed by two levels inverter
The use of long cables in the PWM inverter-motor association generate transient voltage pulses at the inverter which consequently behaves like progressive waves on these cables. Thereby, this phenomenon produces voltage reflection that causes overvoltage problem at the motor terminals. High frequency simulation models for the cables and motors are the key tools to obtain an accurate study of overvoltage problem. In this paper, the high frequency models of cable and induction motor are developed and implemented in Simulink. The simulation results show that the overvoltage at the motor terminals increases when the length of cable and switching frequency increase.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信