在Cipto Mangunkusumo博士的大楼里,改变位置对Critical Care患者的中央静脉压力的影响

Julham Mubarak, Erika Lubis, N. Dewi
{"title":"在Cipto Mangunkusumo博士的大楼里,改变位置对Critical Care患者的中央静脉压力的影响","authors":"Julham Mubarak, Erika Lubis, N. Dewi","doi":"10.56667/jikdi.v1i1.210","DOIUrl":null,"url":null,"abstract":"Many factors would affect the accuracy of Central Venous Pressure (CVP) measurement such as patient’s position during the measuring. Any fault that occurs while measuring could bring a fatal impact such as death. This study aimed to determine the effect of the CVP measuring position towards the results CVP  measurement of critical care patients. This study is a quasi-experimental study with Pre and Post Test design without control by measuring the CVP of 45 respondents with supine and semi-fowler positions. Statistical test using paired samples T-test. The results showed a significant difference in the results of measuring CVP in critical care patients between before and after changing positions with p-value = 0.003. In conclusion, this study indicates that there are differences in the results of the CVP measurement position and it is hoped that nurses can take measurements correctly to avoid any intervention error throughout providing patient care.","PeriodicalId":106541,"journal":{"name":"Jurnal Ilmu Kesehatan Dharmas Indonesia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pengaruh Perubahan Posisi terhadap Hasil Ukur Tekanan Vena Sentral pada Pasien Critical Care di Gedung A RSUPN Dr. Cipto Mangunkusumo\",\"authors\":\"Julham Mubarak, Erika Lubis, N. Dewi\",\"doi\":\"10.56667/jikdi.v1i1.210\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many factors would affect the accuracy of Central Venous Pressure (CVP) measurement such as patient’s position during the measuring. Any fault that occurs while measuring could bring a fatal impact such as death. This study aimed to determine the effect of the CVP measuring position towards the results CVP  measurement of critical care patients. This study is a quasi-experimental study with Pre and Post Test design without control by measuring the CVP of 45 respondents with supine and semi-fowler positions. Statistical test using paired samples T-test. The results showed a significant difference in the results of measuring CVP in critical care patients between before and after changing positions with p-value = 0.003. In conclusion, this study indicates that there are differences in the results of the CVP measurement position and it is hoped that nurses can take measurements correctly to avoid any intervention error throughout providing patient care.\",\"PeriodicalId\":106541,\"journal\":{\"name\":\"Jurnal Ilmu Kesehatan Dharmas Indonesia\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Ilmu Kesehatan Dharmas Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56667/jikdi.v1i1.210\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmu Kesehatan Dharmas Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56667/jikdi.v1i1.210","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

影响中心静脉压(CVP)测量准确性的因素很多,如测量时患者体位等。测量过程中出现的任何故障都可能带来致命的影响,如死亡。本研究旨在探讨危重病人CVP测量位置对CVP测量结果的影响。本研究为准实验研究,采用无控制的前、后测试设计,通过测量45名被调查者仰卧位和半卧位的CVP。统计检验采用配对样本t检验。结果显示,换体位前后重症患者CVP测量结果差异有统计学意义,p值= 0.003。综上所述,本研究表明CVP测量位置的结果存在差异,希望护士能够正确测量,避免在提供患者护理过程中出现干预错误。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pengaruh Perubahan Posisi terhadap Hasil Ukur Tekanan Vena Sentral pada Pasien Critical Care di Gedung A RSUPN Dr. Cipto Mangunkusumo
Many factors would affect the accuracy of Central Venous Pressure (CVP) measurement such as patient’s position during the measuring. Any fault that occurs while measuring could bring a fatal impact such as death. This study aimed to determine the effect of the CVP measuring position towards the results CVP  measurement of critical care patients. This study is a quasi-experimental study with Pre and Post Test design without control by measuring the CVP of 45 respondents with supine and semi-fowler positions. Statistical test using paired samples T-test. The results showed a significant difference in the results of measuring CVP in critical care patients between before and after changing positions with p-value = 0.003. In conclusion, this study indicates that there are differences in the results of the CVP measurement position and it is hoped that nurses can take measurements correctly to avoid any intervention error throughout providing patient care.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信