评估在越南胡志明市测量PM2.5浓度的低成本传感器的适用性

C. D. Nguyen, Hien Thi To
{"title":"评估在越南胡志明市测量PM2.5浓度的低成本传感器的适用性","authors":"C. D. Nguyen, Hien Thi To","doi":"10.32508/stdj.v22i3.1688","DOIUrl":null,"url":null,"abstract":"Introduction: Continuous monitoring provides real-time data which is helpful for measuring air quality; however, these systems are often very expensive, especially for developing countries such as Vietnam. The use of low-cost sensors for monitoring air pollution is a new approach in Vietnam and this study assesses the utility of low-cost, light-scattering-based, particulate sensors for measuring PM2.5 concentrations in Ho Chi Minh City. \nMethods: The low-cost sensors were compared with both a Beta attenuation monitor (BAM) reference method and a gravimetric method during the rainy season period of October to December 2018. \nResults: The results showed that there was a very strong correlation between two low-cost sensors (R = 0.97, slope = 1.0), and that the sensor precision varied from 0 to 21.4% with a mean of 3.1%. Both one-minute averaged data and one-hour averaged data showed similar correlations between sensors and BAM (R2 = 0.62 and 0.69, respectively), while 24-hour averaged data showed excellent agreement (R2 = 0.95, slope = 1.05). In addition, we also found a strong correlation between those instruments and a gravimetric method using 24-hour averaged data. A linear regression was used to calibrate the 24-hour averaged sensor data and, once calibrated, the bias dropped to zero. \nConclusion: These results show that low-cost sensors can be used for daily measurements of PM2.5 concentrations in Ho Chi Minh City. The effect of air conditions, such as temperature and humidity, should be conducted. Moreover, technical methods to improve time resolution of lowcost sensors need to be developed and applied in order to provide real-time measurements at an inexpensive cost. \n ","PeriodicalId":285953,"journal":{"name":"Science and Technology Development Journal","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Evaluating the applicability of a low-cost sensor for measuring PM2.5 concentration in Ho Chi Minh city, Viet Nam\",\"authors\":\"C. D. Nguyen, Hien Thi To\",\"doi\":\"10.32508/stdj.v22i3.1688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Continuous monitoring provides real-time data which is helpful for measuring air quality; however, these systems are often very expensive, especially for developing countries such as Vietnam. The use of low-cost sensors for monitoring air pollution is a new approach in Vietnam and this study assesses the utility of low-cost, light-scattering-based, particulate sensors for measuring PM2.5 concentrations in Ho Chi Minh City. \\nMethods: The low-cost sensors were compared with both a Beta attenuation monitor (BAM) reference method and a gravimetric method during the rainy season period of October to December 2018. \\nResults: The results showed that there was a very strong correlation between two low-cost sensors (R = 0.97, slope = 1.0), and that the sensor precision varied from 0 to 21.4% with a mean of 3.1%. Both one-minute averaged data and one-hour averaged data showed similar correlations between sensors and BAM (R2 = 0.62 and 0.69, respectively), while 24-hour averaged data showed excellent agreement (R2 = 0.95, slope = 1.05). In addition, we also found a strong correlation between those instruments and a gravimetric method using 24-hour averaged data. A linear regression was used to calibrate the 24-hour averaged sensor data and, once calibrated, the bias dropped to zero. \\nConclusion: These results show that low-cost sensors can be used for daily measurements of PM2.5 concentrations in Ho Chi Minh City. The effect of air conditions, such as temperature and humidity, should be conducted. Moreover, technical methods to improve time resolution of lowcost sensors need to be developed and applied in order to provide real-time measurements at an inexpensive cost. \\n \",\"PeriodicalId\":285953,\"journal\":{\"name\":\"Science and Technology Development Journal\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science and Technology Development Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32508/stdj.v22i3.1688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology Development Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32508/stdj.v22i3.1688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

简介:连续监测提供实时数据,有助于空气质量的测量;然而,这些系统往往非常昂贵,特别是对越南这样的发展中国家来说。在越南,使用低成本传感器监测空气污染是一种新方法,本研究评估了在胡志明市使用低成本、基于光散射的颗粒物传感器测量PM2.5浓度的效用。方法:在2018年10 - 12月的雨季期间,将低成本传感器与Beta衰减监测(BAM)参考方法和重力法进行比较。结果:两种低成本传感器之间存在很强的相关性(R = 0.97,斜率= 1.0),传感器精度范围为0 ~ 21.4%,平均值为3.1%。1分钟平均数据和1小时平均数据显示传感器与BAM之间具有相似的相关性(R2分别为0.62和0.69),而24小时平均数据显示非常一致(R2 = 0.95,斜率= 1.05)。此外,我们还发现这些仪器与使用24小时平均数据的重力方法之间存在很强的相关性。线性回归用于校准24小时平均传感器数据,一旦校准,偏差降至零。结论:这些结果表明,低成本的传感器可以用于胡志明市PM2.5浓度的日常测量。应进行温度、湿度等空气条件的影响。此外,为了以低廉的成本提供实时测量,需要开发和应用提高低成本传感器时间分辨率的技术方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating the applicability of a low-cost sensor for measuring PM2.5 concentration in Ho Chi Minh city, Viet Nam
Introduction: Continuous monitoring provides real-time data which is helpful for measuring air quality; however, these systems are often very expensive, especially for developing countries such as Vietnam. The use of low-cost sensors for monitoring air pollution is a new approach in Vietnam and this study assesses the utility of low-cost, light-scattering-based, particulate sensors for measuring PM2.5 concentrations in Ho Chi Minh City. Methods: The low-cost sensors were compared with both a Beta attenuation monitor (BAM) reference method and a gravimetric method during the rainy season period of October to December 2018. Results: The results showed that there was a very strong correlation between two low-cost sensors (R = 0.97, slope = 1.0), and that the sensor precision varied from 0 to 21.4% with a mean of 3.1%. Both one-minute averaged data and one-hour averaged data showed similar correlations between sensors and BAM (R2 = 0.62 and 0.69, respectively), while 24-hour averaged data showed excellent agreement (R2 = 0.95, slope = 1.05). In addition, we also found a strong correlation between those instruments and a gravimetric method using 24-hour averaged data. A linear regression was used to calibrate the 24-hour averaged sensor data and, once calibrated, the bias dropped to zero. Conclusion: These results show that low-cost sensors can be used for daily measurements of PM2.5 concentrations in Ho Chi Minh City. The effect of air conditions, such as temperature and humidity, should be conducted. Moreover, technical methods to improve time resolution of lowcost sensors need to be developed and applied in order to provide real-time measurements at an inexpensive cost.  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信