Anton Sudiyanto, Riria Zendy Mirahati, Natasya Aulia Rahma
{"title":"PENGARUH DRYING ELEKTRODA LOW HYDROGEN PADA LONGITUDINAL WELD PENSTOCK MATERIAL BAJA SM 400 B TERHADAP CACAT LAS DENGAN INSPEKSI NON DESTRUCTIVE TEST METODE RADIOGRAFI","authors":"Anton Sudiyanto, Riria Zendy Mirahati, Natasya Aulia Rahma","doi":"10.31315/jmept.v2i2.6510","DOIUrl":null,"url":null,"abstract":"PT. Barata Indonesia (Persero) Tegal Water Resources Division is one of the hydromechanical workshops that focus on the construction of water buildings such as Penstock, valves, trashrack water gates on the dam and flood controlling pumps. Penstock is a channel that connects the water reservoir from the dam to the turbine in the power plant building. In the study entitled \"The Effect of Low Hydrogen Electrode Drying on Longitudinal Weld Penstock Steel SM 400 B Material Against Welding Defects With Non-Destructive Inspection Test Radiographic Methods\" was carried out to determine the comparison of the welding results of the penstock components using the condition of the electrodes being dried and without being drying and its effect on welding defects produced by inspection of the non-destructive test radiography. The first method of testing is to search for supporting literature, collect field data, carry out radiographic testing, film reading and interpretation of defects. The parent metal used is SM 400 B steel which has been Mill Test certified and has perfect weldability. The welding process is carried out using the SMAW method using the E7016 electrode. Based on research that has been done, the welding defect identified is the Wormhole Porosity cluster. As for the possibility of disability occurs because of the insecure storage and treatment of electrodes, and the weather intervention due to welding is carried out in the open.","PeriodicalId":196240,"journal":{"name":"Journal of Metallurgical Engineering and Processing Technology","volume":"497 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Metallurgical Engineering and Processing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31315/jmept.v2i2.6510","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
PT. Barata Indonesia (Persero) legal Water Resources Division是水机械车间之一,专注于水建筑的建造,如Penstock,阀门,大坝上的垃圾水闸和防洪泵。压力管道是连接电站建筑物内水库和水轮机的通道。在题为“低氢电极干燥对纵向焊接压力管钢sm400b材料焊接缺陷的影响与无损检测射线照相方法”的研究中,进行了确定在电极干燥和不干燥的情况下压力管部件的焊接结果的比较,以及其对无损检测射线照相检查产生的焊接缺陷的影响。第一种检测方法是查找支持性文献,收集现场资料,进行射线检测,胶片阅读和缺陷解释。母材为sm400b钢,已通过工厂测试认证,具有完美的可焊性。采用E7016焊条,采用SMAW法进行焊接。根据已有的研究,确定的焊接缺陷是虫孔孔隙团簇。由于电极的储存和处理不安全,以及由于焊接引起的天气干预是在露天进行的,可能会发生致残。
PENGARUH DRYING ELEKTRODA LOW HYDROGEN PADA LONGITUDINAL WELD PENSTOCK MATERIAL BAJA SM 400 B TERHADAP CACAT LAS DENGAN INSPEKSI NON DESTRUCTIVE TEST METODE RADIOGRAFI
PT. Barata Indonesia (Persero) Tegal Water Resources Division is one of the hydromechanical workshops that focus on the construction of water buildings such as Penstock, valves, trashrack water gates on the dam and flood controlling pumps. Penstock is a channel that connects the water reservoir from the dam to the turbine in the power plant building. In the study entitled "The Effect of Low Hydrogen Electrode Drying on Longitudinal Weld Penstock Steel SM 400 B Material Against Welding Defects With Non-Destructive Inspection Test Radiographic Methods" was carried out to determine the comparison of the welding results of the penstock components using the condition of the electrodes being dried and without being drying and its effect on welding defects produced by inspection of the non-destructive test radiography. The first method of testing is to search for supporting literature, collect field data, carry out radiographic testing, film reading and interpretation of defects. The parent metal used is SM 400 B steel which has been Mill Test certified and has perfect weldability. The welding process is carried out using the SMAW method using the E7016 electrode. Based on research that has been done, the welding defect identified is the Wormhole Porosity cluster. As for the possibility of disability occurs because of the insecure storage and treatment of electrodes, and the weather intervention due to welding is carried out in the open.