2016-2019年英国乳房筛查项目中的辐射剂量。

J. Loveland, K. Young, J. Oduko, Alistair Mackenzie
{"title":"2016-2019年英国乳房筛查项目中的辐射剂量。","authors":"J. Loveland, K. Young, J. Oduko, Alistair Mackenzie","doi":"10.1259/bjr.20211400","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nTo record the radiation doses involved in UK breast screening and to identify any changes since previous publications related to technical factors and the population screened.\n\n\nMETHODS\nMammographic exposure factors for 68,998 women imaged using 411 X-ray sets spread across the UK were compiled. Local output and half value layer measurements for each X-ray set were used to estimate mean glandular dose (MGD) using the standard UK method.\n\n\nRESULTS\nMean MGDs in digital mammography have increased by 11% since 2010-12 for both medio-lateral oblique (MLO) and cranio-caudal (CC) views. The mean compressed breast thickness (CBT) has increased (4.8% CC, 5.2% MLO) over the same period. The mean MLO CBT value of 62.4 ± 0.1 mm is outside the 50 to 60 mm range used for diagnostic reference levels. The increase in MGD is consistent with the CBT changes. The mean MGD in the 50 to 60 mm CBT range is 1.44 ± 0.03 mGy for MLO views. CBT varies with age and peaks at 51.\n\n\nCONCLUSIONS\nMean CBT has increased with time, and this has increased mean MGDs for digital mammography. CBT also varies with age.\n\n\nADVANCES IN KNOWLEDGE\nUpdated average MGDs in the UK are provided. There is evidence that breast size is increasing in the UK and that mean CBT is affected by age related changes in the breast.","PeriodicalId":226783,"journal":{"name":"The British journal of radiology","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Radiation doses in the united Kingdom breast screening programmes 2016-2019.\",\"authors\":\"J. Loveland, K. Young, J. Oduko, Alistair Mackenzie\",\"doi\":\"10.1259/bjr.20211400\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES\\nTo record the radiation doses involved in UK breast screening and to identify any changes since previous publications related to technical factors and the population screened.\\n\\n\\nMETHODS\\nMammographic exposure factors for 68,998 women imaged using 411 X-ray sets spread across the UK were compiled. Local output and half value layer measurements for each X-ray set were used to estimate mean glandular dose (MGD) using the standard UK method.\\n\\n\\nRESULTS\\nMean MGDs in digital mammography have increased by 11% since 2010-12 for both medio-lateral oblique (MLO) and cranio-caudal (CC) views. The mean compressed breast thickness (CBT) has increased (4.8% CC, 5.2% MLO) over the same period. The mean MLO CBT value of 62.4 ± 0.1 mm is outside the 50 to 60 mm range used for diagnostic reference levels. The increase in MGD is consistent with the CBT changes. The mean MGD in the 50 to 60 mm CBT range is 1.44 ± 0.03 mGy for MLO views. CBT varies with age and peaks at 51.\\n\\n\\nCONCLUSIONS\\nMean CBT has increased with time, and this has increased mean MGDs for digital mammography. CBT also varies with age.\\n\\n\\nADVANCES IN KNOWLEDGE\\nUpdated average MGDs in the UK are provided. There is evidence that breast size is increasing in the UK and that mean CBT is affected by age related changes in the breast.\",\"PeriodicalId\":226783,\"journal\":{\"name\":\"The British journal of radiology\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The British journal of radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1259/bjr.20211400\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The British journal of radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1259/bjr.20211400","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的记录英国乳腺筛查所涉及的辐射剂量,并确定自先前与技术因素和筛查人群相关的出版物以来的任何变化。方法收集68,998名女性的x射线暴露因子,这些女性使用了遍布英国的411台x射线设备。使用标准英国方法,使用每组x射线的局部输出和半值层测量来估计平均腺体剂量(MGD)。结果自2010- 2012年以来,数字乳房x线摄影中侧斜位(MLO)和颅尾位(CC)的平均MGDs增加了11%。同期平均压缩乳房厚度(CBT)增加(4.8% CC, 5.2% MLO)。平均MLO CBT值为62.4±0.1 mm,超出了用于诊断参考水平的50至60 mm范围。MGD的增加与CBT的变化一致。在50 ~ 60mm CBT范围内,MLO视图的平均MGD为1.44±0.03 mGy。CBT随年龄变化,在51岁时达到顶峰。结论:随着时间的推移,平均CBT增加,这增加了数字乳房x线摄影的平均MGDs。CBT也随年龄而变化。知识的进步提供了英国最新的平均MGDs。有证据表明,英国的乳房尺寸正在增加,这意味着CBT受到与乳房年龄相关的变化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiation doses in the united Kingdom breast screening programmes 2016-2019.
OBJECTIVES To record the radiation doses involved in UK breast screening and to identify any changes since previous publications related to technical factors and the population screened. METHODS Mammographic exposure factors for 68,998 women imaged using 411 X-ray sets spread across the UK were compiled. Local output and half value layer measurements for each X-ray set were used to estimate mean glandular dose (MGD) using the standard UK method. RESULTS Mean MGDs in digital mammography have increased by 11% since 2010-12 for both medio-lateral oblique (MLO) and cranio-caudal (CC) views. The mean compressed breast thickness (CBT) has increased (4.8% CC, 5.2% MLO) over the same period. The mean MLO CBT value of 62.4 ± 0.1 mm is outside the 50 to 60 mm range used for diagnostic reference levels. The increase in MGD is consistent with the CBT changes. The mean MGD in the 50 to 60 mm CBT range is 1.44 ± 0.03 mGy for MLO views. CBT varies with age and peaks at 51. CONCLUSIONS Mean CBT has increased with time, and this has increased mean MGDs for digital mammography. CBT also varies with age. ADVANCES IN KNOWLEDGE Updated average MGDs in the UK are provided. There is evidence that breast size is increasing in the UK and that mean CBT is affected by age related changes in the breast.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信