局部放电的在线测量

N. Srinivas, N. Ahmed, G. Raju
{"title":"局部放电的在线测量","authors":"N. Srinivas, N. Ahmed, G. Raju","doi":"10.1109/CEIDP.2000.884049","DOIUrl":null,"url":null,"abstract":"On line measurement of partial discharges of equipment while in service has a great deal of potential in saving equipment down time in gas insulated substations (GIS) and gas insulated transmission lines (GITL). To address this aspect of partial discharge measurement there is scope for considerable progress particularly in the area of cables already is service. The laboratory measurement of high frequency current signals or emitted radio frequency signals is a relatively easier proposition than to measure PD in a cable that is already in service. One of the major constraints in on-line measurement of PD in cables is the attenuation in solid cables imposing a theoretical limitation to the PD measurement. The attenuation in a solid polythene cable has been numerically calculated and the effect of sheath is demonstrated.","PeriodicalId":414762,"journal":{"name":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"On line measurement of partial discharges\",\"authors\":\"N. Srinivas, N. Ahmed, G. Raju\",\"doi\":\"10.1109/CEIDP.2000.884049\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On line measurement of partial discharges of equipment while in service has a great deal of potential in saving equipment down time in gas insulated substations (GIS) and gas insulated transmission lines (GITL). To address this aspect of partial discharge measurement there is scope for considerable progress particularly in the area of cables already is service. The laboratory measurement of high frequency current signals or emitted radio frequency signals is a relatively easier proposition than to measure PD in a cable that is already in service. One of the major constraints in on-line measurement of PD in cables is the attenuation in solid cables imposing a theoretical limitation to the PD measurement. The attenuation in a solid polythene cable has been numerically calculated and the effect of sheath is demonstrated.\",\"PeriodicalId\":414762,\"journal\":{\"name\":\"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2000.884049\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2000.884049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

气体绝缘变电站(GIS)和气体绝缘输电线路(GITL)在运行中对设备局部放电进行在线测量,对于节省设备停机时间具有很大的潜力。为了解决局部放电测量的这一方面,特别是在电缆已经服务的领域,有相当大的进展空间。实验室测量高频电流信号或发射的射频信号比测量已经在使用的电缆中的PD相对容易。固体电缆的衰减是在线测量电缆放电特性的主要制约因素之一,从理论上限制了电缆放电特性的测量。对实心聚乙烯电缆的衰减进行了数值计算,论证了护套对电缆衰减的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On line measurement of partial discharges
On line measurement of partial discharges of equipment while in service has a great deal of potential in saving equipment down time in gas insulated substations (GIS) and gas insulated transmission lines (GITL). To address this aspect of partial discharge measurement there is scope for considerable progress particularly in the area of cables already is service. The laboratory measurement of high frequency current signals or emitted radio frequency signals is a relatively easier proposition than to measure PD in a cable that is already in service. One of the major constraints in on-line measurement of PD in cables is the attenuation in solid cables imposing a theoretical limitation to the PD measurement. The attenuation in a solid polythene cable has been numerically calculated and the effect of sheath is demonstrated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信