{"title":"隔离电流互感器现场标定系统","authors":"E. Mohns","doi":"10.1109/CPEM.2010.5545013","DOIUrl":null,"url":null,"abstract":"An on-site calibration system for three-phase isolation current transformers is described. It is based on precise power comparators which are shipped to the customer. Measurements can be done at test currents up to 120 A. The measurement uncertainties of the self-calibrating measurement system are in the order of 0.005 % for the ratio error and 0.01 crad for the phase displacement at power frequencies.","PeriodicalId":222495,"journal":{"name":"CPEM 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"On-site calibration system for isolation current transformers\",\"authors\":\"E. Mohns\",\"doi\":\"10.1109/CPEM.2010.5545013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An on-site calibration system for three-phase isolation current transformers is described. It is based on precise power comparators which are shipped to the customer. Measurements can be done at test currents up to 120 A. The measurement uncertainties of the self-calibrating measurement system are in the order of 0.005 % for the ratio error and 0.01 crad for the phase displacement at power frequencies.\",\"PeriodicalId\":222495,\"journal\":{\"name\":\"CPEM 2010\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CPEM 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2010.5545013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CPEM 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2010.5545013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-site calibration system for isolation current transformers
An on-site calibration system for three-phase isolation current transformers is described. It is based on precise power comparators which are shipped to the customer. Measurements can be done at test currents up to 120 A. The measurement uncertainties of the self-calibrating measurement system are in the order of 0.005 % for the ratio error and 0.01 crad for the phase displacement at power frequencies.